Permit Details

Status:
Expired
Type:
COMMERCIAL OTHER
Address NEW:
8620 E TANQUE VERDE RD
Apply Date:
05/27/2004
Applicant:
WELMAN SPERIDES MICKELBERG ARCHIT.
Description:
GRADING:FIRE STATION #21
Contractors:
  • SUNDT CORP

Permit Reviews

Permit Number - T04BU01265
Permit Status: Expired
Permit Description: GRADING:FIRE STATION #21
Start Date Submittal Complete Date Status  
05/27/2004 PLANS OK TO SUBMIT - GRADING 05/27/2004 COMPLETED Review Details
05/27/2004 GRADING 06/23/2004 COMPLETED Review Details
06/30/2004 RESUBMITTAL - GRADING ALL 08/06/2004 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04BU01265
Permit Status: Expired
Permit Description: GRADING:FIRE STATION #21
Total Outstanding Activity Conditions - 2
Date Name
05/27/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
07/23/2004 LANDSCAPE INSPECTOR MUST CHECK FENCING OF NATURAL AREAS PRIOR TO GRUBBING OR GRADING.

Outstanding Inspections

Permit Status: Expired
Permit Number: T04BU01265
Permite Description: GRADING:FIRE STATION #21
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
STORMWATER FINAL INSPECTION N/A Not Inspected
04/29/2005 GRADING - FINAL N/A Partial Approval THE FOLLOWING ITEMS STILL NEED TO BE ADDRESSED PRIOR TO THE APPROVAL OF THE FINAL GRADING. ITEMS #1 AND 2 NEED APPROVALS FROM BOTH ENGINEERING AND ZONING. ITEMS #4 AND 8 NEED TO BE ADDRESSED BY THE PROJECT ENGINEER.

1. PROVIDE CURBS ON THE WEST SIDE OF THE PARKING ISLANDS ON BOTH NORTH AND SOUTH PARKING AREAS.
2. PROVIDE A WATER HARVEST BASIN AT THE SOUTHWEST CORNER OF THE BUILDING.
4. VERIFY RETENTION BASIN "S2" BOTTOM ELEVATION AND PROVIDE 0.3% POSITIVE DRAINAGE FLOW TO 4" PVC BLEEDER PIPE AT THE BASE OF THE WEIR.
8. PROVIDE AN ARIZONA REGISTERED PROFESSIONAL ENGINEER'S CERTIFIED INSPECTION REPORT FOR THE DRAINAGE AND DETENTION/RETENTION FACILITIES.

NOTE:THE ROCK RIP-RAP DOES NOT EXTEND TO THE TOE OF SLOPE IN THE R/D BASIN, FROM THE (6) WALL OPENINGS ON THE SOUTHWEST SIDE OF THE SITE .
RECOMMENDATION: PROVIDE ROCK RIP RAP TO THE TOE OF SLOPE.

Completed Inspections

Permit Status: Expired
Permit Number: T04BU01265
Permit Description: GRADING:FIRE STATION #21
Total Completed Inspections - 4
Date Description Inspector Results Comments
07/28/2004 NPPO PRE PERMIT INSPECTION ACONNOR Approved
08/20/2004 ENGINEERING PRE-CONSTRUCTION JBRUCKME Approved PRE-CONSTRUCTION MEETING WITH SUNDT CONST.
BUTCH HECKEL 241-3947
DOUG BOLEN 591-3486
09/07/2004 STORMWATER INSTALL OF CONTROLS JBRUCKME Approved INSTALLATION OF STABILIZED CONSTRUCTION ENTRANCE AND THE SILT FENCE ON SOUTH AND WEST PERIMETERS IS COMPLETE.
12/22/2004 STORMWATER FOLLOW-UP INSP JBRUCKME Approved PROVIDE A V-DITCH/BERM IN LIEU OF SILT FENCE AT THE TEMPORARY OPENING IN THE SOUTH FENCE.