Permit: T03PL02022
Permit Details
Apply Date:
12/04/2003
Applicant:
VICTOR GARRIDO
Description:
REPLACE:GASLINE & WATER HEATER
Permit Reviews
Permit Number - T03PL02022
Permit Status: Final
Permit Description: REPLACE:GASLINE & WATER HEATER
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 12/04/2003 | PLUMBING | 12/04/2003 | COMPLETED |
| 12/08/2003 | PLUMBING | 12/08/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03PL02022
Permit Status: Final
Permit Description: REPLACE:GASLINE & WATER HEATER
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/04/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T03PL02022
Permit Description: REPLACE:GASLINE & WATER HEATER
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/17/2003 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection 0000* |
| 12/26/2003 | PLUMBING - GAS RECONNECT | RRICH | Approved | IVRS - Inspection 0000* NO ONE HOME |
| 12/30/2003 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection 0000*/ 1) INSTALL 90o ELL ON T&P TERMINUS. 2) SINGLE WALL VENT CONNECTOR REQUIRES 6" OF CLEARANCE FROM COMBUSTABLES. NOTE: DOUBLE WALL REQUIRES ONLY 1". 3) USE METAL BACK TAPE, NOT DUCT TAPE. SUPPORT VENT SYSTEM. |
| 01/26/2004 | PERMIT FINALED | RMYERS | Approved |