Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
1070 E GINTER RD #15
Apply Date:
10/27/2003
Applicant:
MARTHA COTA
Description:
GASLINE:REPAIR

Permit Reviews

Permit Number - T03PL01790
Permit Status: Expired
Permit Description: GASLINE:REPAIR
Start Date Submittal Complete Date Status  
10/27/2003 PLUMBING 10/27/2003 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T03PL01790
Permit Status: Expired
Permit Description: GASLINE:REPAIR
Total Outstanding Activity Conditions - 1
Date Name
10/27/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T03PL01790
Permite Description: GASLINE:REPAIR
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
10/29/2003 PLUMBING - FINAL N/A Denied IVRS - Inspection 0999*/ 1) MUST PROVIDE PRESSURE GAUGE WITH 1/10 TH INCREMENTS. 2) WHEN A MASTER METER HAS BEEN LOCKED BY S.W. GAS THEN A LICENSED PLUMBING CONTRACTOR WILL HAVE TO GO THROUGH EACH UNIT THAT IS SUPPLIED BY MASTER METER AND BEING ALL APPLIANCES AND SYSTEM TO CURRENT CODE. THEN I WILL INSPECT EACH UNIT FOR COMPLIANCE PRIOR TO RELEASE OF GAS CLEARANCE CACO. 3) MUST PROVIDE TAPE PRIMER AND APPROVED 10 MIL. TAPE ON JOINTS UNDERGROUND.