Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
2817 E KAIBAB VISTA
Apply Date:
03/04/2003
Applicant:
SCOTT COVERDALE
Description:
REPLACE:GAS LINE

Permit Reviews

Permit Number - T03PL00420
Permit Status: Expired
Permit Description: REPLACE:GAS LINE
Start Date Submittal Complete Date Status  
03/04/2003 PLUMBING 03/04/2003 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T03PL00420
Permit Status: Expired
Permit Description: REPLACE:GAS LINE
Total Outstanding Activity Conditions - 1
Date Name
03/04/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T03PL00420
Permite Description: REPLACE:GAS LINE
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
03/06/2003 PLUMBING - FINAL N/A Denied IVRS - Inspection 0999*
1.) OK TO BACKFILL TRENCH.
2.) MUST PROVIDE ALTERNATE METHOD OF P & T DRAIN FOR WATER HTR A VARIANCE FORM MUST BE OBTAIN SPECIFYING P & T DRAIN TO DISCHARGE INTO WATER HTR DRAIN PAN AND ALTERNATE PRESSURE RELIFE VALVE PRE SET @ 125 PSI @ EXTERIOR C.W. SUPPLY. FORM MUST BE ON SITE @ TIME OF INSPECTION.
3.) MUST SCREW DOWN FLU VENT FOR WATER HTR (3) SCREWS PER JOINT.
4.) MUST CAP OFF GAS SUPPLY TO FURANCE OR INSTALL REGULATOR FOR FURNACE.

Completed Inspections

Permit Status: Expired
Permit Number: T03PL00420
Permit Description: REPLACE:GAS LINE
Total Completed Inspections - 2
Date Description Inspector Results Comments
03/14/2003 PLUMBING - GAS PRESS TEST FNL TRINIVJR Approved IVRS - Inspection 0000*
03/14/2003 PLUMBING - GAS PRESSURE TEST TRINIVJR Approved IVRS - Inspection 0000*GAS PRESSURE TEST IS OK
ALL CORRECTIONS HAVE BEEN MADE.

Documents

File Name Document Type  
None DOCUMENTS VIEW