Permit: T03PL00420

Parcel: 132091990


Addresses:

2817 E KAIBAB VISTA

Inspection Status: Denied

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/06/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*
1.) OK TO BACKFILL TRENCH.
2.) MUST PROVIDE ALTERNATE METHOD OF P & T DRAIN FOR WATER HTR A VARIANCE FORM MUST BE OBTAIN SPECIFYING P & T DRAIN TO DISCHARGE INTO WATER HTR DRAIN PAN AND ALTERNATE PRESSURE RELIFE VALVE PRE SET @ 125 PSI @ EXTERIOR C.W. SUPPLY. FORM MUST BE ON SITE @ TIME OF INSPECTION.
3.) MUST SCREW DOWN FLU VENT FOR WATER HTR (3) SCREWS PER JOINT.
4.) MUST CAP OFF GAS SUPPLY TO FURANCE OR INSTALL REGULATOR FOR FURNACE.