Permit: T03ME00707
Permit Details
Apply Date:
12/04/2003
Applicant:
RUSSETT SERVICE CORPORATION, *C
Description:
REPLACEMENT:(2) GAS/ELEC UNIT APA
Contractors:
- RUSSETT SERVICE CORPORATION, *C
Outstanding Activity Conditions
Permit Number - T03ME00707
Permit Status: Expired
Permit Description: REPLACEMENT:(2) GAS/ELEC UNIT APA
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/04/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T03ME00707
Permite Description: REPLACEMENT:(2) GAS/ELEC UNIT APA
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/08/2003 | MECHANICAL - FINAL | N/A | Denied | IVRS - Inspection 0999*/ 1) PROVIDE A ROOF JACK WHERE CONDENSATE DRAINS PENETRATE THE ROOF. 2) PROVIDE A PRESSURE TEST ON ALL NEW GAS PIPING. ½" GAS PIPE NOT ADEQUATE FOR 125,000 BTU, IF OVER 20'. 3) THE SHIELD OVER CANVAS CONNECTORS MUST COVER THE SIDES ALAO. 4) FRESH AIR INTAKE ON SOUTH UNIT IS TOO CLOSE TO A FLUE VENT PIPE. 5) PAINT EXPOSED PVC ON SIDE OF BLDG. AND SECURE TO WALL. EXTEND DRAIN TO WITHIN 6" OF THE DIRT. NEED ACCESS TO INSIDE OF BLDG TO SEE WHERE GAS IS CONNECTED. |