Permit: T03EL02199
Permit Details
Apply Date:
11/06/2003
Applicant:
DAY STAR SERVICE CO INC *C
Description:
ELECTRIC:UPGRADE 200 AMP/ADD 1 CIRCUIT TO STOVE/REPLACE SUBPANEL (APA)
Contractors:
- DAY STAR SERVICE CO INC *C
Outstanding Activity Conditions
Permit Number - T03EL02199
Permit Status: Expired
Permit Description: ELECTRIC:UPGRADE 200 AMP/ADD 1 CIRCUIT TO STOVE/REPLACE SUBPANEL (APA)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/06/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T03EL02199
Permite Description: ELECTRIC:UPGRADE 200 AMP/ADD 1 CIRCUIT TO STOVE/REPLACE SUBPANEL (APA)
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/18/2003 | ELECTRIC - FINAL | N/A | Partial Approval | IVRS - Inspection 0000*/ 1) A GAS BOND IS NEEDED PER CODE 250.104 2) A CHASE NIPPLE IS NOT AN APPROVED FITTING FOR USE WITH A LB 3) PLEASE CORRECTLY LABEL BREAKER AS SUB PANEL 4) HAVE RANGE CIRCUIT ADDED TO PERMIT AND PLEASE PROVIDE ACCESS FOR INSPECTION |