Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Withdrwn
Type:
COMMERCIAL OTHER
Address:
4801 S 12TH AV
Address NEW:
4801 S 12TH AV
Apply Date:
07/10/2003
Applicant:
BREEZE WAYS INC*C
Description:
UPGRADE:ELECTRIC 200AMP (REPLACE) (APA)
Contractors:
  • BREEZE WAYS INC*C

Outstanding Activity Conditions

Permit Number - T03EL01351
Permit Status: Withdrwn
Permit Description: UPGRADE:ELECTRIC 200AMP (REPLACE) (APA)
Total Outstanding Activity Conditions - 1
Date Name
07/10/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Withdrwn
Permit Number: T03EL01351
Permite Description: UPGRADE:ELECTRIC 200AMP (REPLACE) (APA)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
07/11/2003 ELECTRIC - FINAL N/A Denied IVRS - Inspection 0245*/ 1) NEW 200 AMP METER BASE FEED AN EXISTING INDOOR RATED DISCONNECT SWITCH. 2) GUTTER MUST BE RATED FOR OUTDOOR USE. 3) GROUNDING ELECTRODE CONDUCTOR SPLICES MUST BE PERMANANT TYPE PER ART 250 NEC. 4) LOAD CENTER TO RIGHT OF DISCONNECT MUST BE OUTDOOR RATED. CAN SEE DAYLIGHT AT TOP FROM INSIDE. 5) EXPOSED WIRING OUTSIDE. 6) THIS SERVICE AND ASSOCIATED WIRING, EQUIPMENT MUST BE BROUGHT UP TO CODE PRIOR TO POWER RELEASE. UNSAFE AS IS. 7) WORK TO BE DONE BY L-11 LICENSED CONTRACTOR.

Documents

File Name Document Type  
T03EL01351 2025 MASS-UPLOAD.PDF DOCUMENTS VIEW