Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
1010 W LIND ST
Address NEW:
1010 W LIND ST
Apply Date:
11/13/2003
Applicant:
BURNS AND WALD-HOPKINS
Description:
REPLACE:POOL:BATH HOUSE POOL4500SF, SHADED DECK 1188 SF, GUARD SHACK 258SF
Contractors:
  • TL ROOF AND ASSOCIATES

Permit Reviews

Permit Number - T03CM05405
Permit Status: C of o
Permit Description: REPLACE:POOL:BATH HOUSE POOL4500SF, SHADED DECK 1188 SF, GUARD SHACK 258SF
Start Date Submittal Complete Date Status  
02/27/2004 3RD PARTY REVIEW-REVISION/OTHER 03/12/2004 COMPLETED Review Details
11/13/2003 PLANS OK TO SUBMIT - 3RD PARTY 11/13/2003 COMPLETED Review Details
11/13/2003 3RD PARTY REVIEW-COMMERCIAL TI 12/19/2003 COMPLETED Review Details
11/14/2003 3RD PARTY REVIEW-COMMERCIAL 12/03/2003 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T03CM05405
Permit Status: C of o
Permit Description: REPLACE:POOL:BATH HOUSE POOL4500SF, SHADED DECK 1188 SF, GUARD SHACK 258SF
Total Outstanding Activity Conditions - 1
Date Name
11/13/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T03CM05405
Permit Description: REPLACE:POOL:BATH HOUSE POOL4500SF, SHADED DECK 1188 SF, GUARD SHACK 258SF
Total Completed Inspections - 35
Date Description Inspector Results Comments
12/29/2003 ELECTRIC - UNDERGROUND MCAPISTR Approved IVRS - Inspection 0000*
12/29/2003 ELECTRIC - UFER MCAPISTR Approved IVRS - Inspection 0000*
01/15/2004 EXCAVATION/LAYOUT REBAR & ZON AMATHIES Approved IVRS - Inspection 0000*
01/20/2004 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection 0000*/ 1) OK FOR CONCRETE.
01/28/2004 STEM WALL/RETAINING WALL AQUIROZ Approved IVRS - Inspection 0000*
03/01/2004 POOL/SPA ELECTRIC MCAPISTR Approved IVRS - Inspection 0000*
03/02/2004 PLUMBING - SEWER HCS CONNECT RMYERS Approved IVRS - Inspection 0000*/ 1) 4" N/H SEWER OK. 2) TIE-IN AT EXISTING CLAY OK. 3) WTR TEST OK. 4) OK TO BACKFILL.
03/22/2004 ELECTRIC - CABLE DROP MCAPISTR Approved IVRS - Inspection 0000*
03/23/2004 TEP CLEARANCE - AM DROBEY Approved
04/08/2004 BUILDING PRE-SLAB AQUIROZ Approved IVRS - Inspection :*
05/04/2004 POOL/SPA FINAL/BARRIER AQUIROZ Approved IVRS - Inspection :
See detailed listing on site.| 999*
05/04/2004 FRAMING AQUIROZ Approved IVRS - Inspection :
See detailed listing on site.| 999*
05/04/2004 ROOF NAILING AQUIROZ Approved IVRS - Inspection :
See detailed listing on site.| 999*
05/04/2004 EXT METAL CLIPS/EXT SHEATHING AQUIROZ Approved IVRS - Inspection :
See detailed listing on site.| 999*
05/07/2004 PLUMBING - INTERMEDIATE RMYERS Approved 1) Z MECHANICAL FLANGES IN MENS ROOM AND ALL CAULKED FLANGES IN WOMEN'S ROOM OK
2) OK TO COVER ALL AREAS
05/19/2004 POOL/SPA PLUMBING RMYERS Approved IVRS - Inspection :*
05/19/2004 POOL/SPA PRE-GUNITE AQUIROZ Approved IVRS - Inspection :*
05/19/2004 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection :*/ PROVIDE LETTER FROM ENGINEER ABOUT STATUS OF REMOTE BULB TO AC1, AND FUNCTION/PURPOSE OF, OR DELETE.
05/19/2004 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection :*
05/24/2004 NPPO - FINAL ACONNOR Approved
05/24/2004 LANDSCAPE - FINAL ACONNOR Approved
05/24/2004 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*/ 1) CORRECTIONS MADE OK. 2) OK FOR C OF O PENDING ANY OTHER INSPECTION.
05/24/2004 OUTDOOR LIGHTING FINAL DSANTACR Approved IVRS - Inspection :*
05/24/2004 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection :*/ OK C OF O.
05/24/2004 ELECTRIC - INTERMEDIATE DSANTACR Approved IVRS - Inspection :*
05/24/2004 REINFORCED MASONRY PRE-GROUT AQUIROZ Approved IVRS - Inspection :*
05/25/2004 RIGHT OF WAY - FINAL LLOPEZ Approved
05/25/2004 ENGINEERING - FINAL JSALINE Approved C OF O APPROVED.
05/26/2004 SIGN - FINAL CSTEPHEN Approved SIGN PERMIT ISSUED
05/26/2004 SIGN - FINAL CSTEPHEN Approved needs to obtain sign permit for new "Jacobs Pool" freestanding sign.
05/26/2004 FIRE - FINAL LLAKEY Approved
05/26/2004 BUILDING - FINAL AQUIROZ Approved IVRS - Inspection :*
05/27/2004 HEALTH DEPT - FINAL 724-7908 RVEGA Approved
05/28/2004 PERMIT FINALED EGRANT Approved
05/28/2004 MECHANICAL - FINAL CWILLIAM Approved OK PER CHUCK WILLIAMS BY PHONE

Documents

File Name Document Type  
001_G1.2.TIF CONSTRPLANS VIEW
002_L0.4.TIF CONSTRPLANS VIEW
None CONSTRPLANS VIEW
C OF O_05-28-2004.TIF CERT OF OCC VIEW
STRUCCALC.TIF DOCUMENTS VIEW
STRUCTURALDESIGNCOMPUTATIONS.TIF DOCUMENTS VIEW
WATERWHEELSPECS.TIF DOCUMENTS VIEW
CONSTRUCTIONDOCUMENTS_01.TIF DOCUMENTS VIEW
CONSTRUCTIONDOCUMENTS_02.TIF DOCUMENTS VIEW
CONSTRUCTIONDOCUMENTS_03.TIF DOCUMENTS VIEW
CONSTRUCTIONDOCUMENTS_04.TIF DOCUMENTS VIEW
CONSTRUCTIONDOCUMENTS_05.TIF DOCUMENTS VIEW
CONSTRUCTIONDOCUMENTS_06.TIF DOCUMENTS VIEW
CONSTRUCTIONDOCUMENTS_07.TIF DOCUMENTS VIEW
None DOCUMENTS VIEW