Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
1140 N 2ND AV
Apply Date:
11/07/2003
Applicant:
ROBERT HARRIS
Description:
UPGRADE:ELECTRIC/PLUMBING/MECHANICAL/T03VL00784

Permit Reviews

Permit Number - T03CM05310
Permit Status: Expired
Permit Description: UPGRADE:ELECTRIC/PLUMBING/MECHANICAL/T03VL00784
Start Date Submittal Complete Date Status  
01/30/2004 REVISION 01/30/2004 COMPLETED Review Details
11/07/2003 OTHER 12/05/2003 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T03CM05310
Permit Status: Expired
Permit Description: UPGRADE:ELECTRIC/PLUMBING/MECHANICAL/T03VL00784
Total Outstanding Activity Conditions - 1
Date Name
11/07/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T03CM05310
Permite Description: UPGRADE:ELECTRIC/PLUMBING/MECHANICAL/T03VL00784
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
PLUMBING - FINAL N/A Not Inspected
MECHANICAL - FINAL N/A Not Inspected
02/13/2006 ELECTRIC - FINAL N/A Denied 1) VACUUM BREAKERS HOSE BIBS
2) BEDROOM CIRCUITS MUST BE ARC FAULT PROTECTED
3) INSTALL ANTI-TILT AT STOVE
4) PROVIDE 1" CLEARANCE FROM COMBUSTIBLES AT WATER HEATER FLUE
5) MISSING DEAD FRONT COVER ALL CONDENSOR DISCONNECT
6) SECURE A/C DISCONNECT LIQUID TIGHT 12" FROM BOX

Completed Inspections

Permit Status: Expired
Permit Number: T03CM05310
Permit Description: UPGRADE:ELECTRIC/PLUMBING/MECHANICAL/T03VL00784
Total Completed Inspections - 7
Date Description Inspector Results Comments
03/05/2004 PLUMBING - YARD WTR LINE/TEST FGREER Approved IVRS - Inspection 0000*
03/12/2004 PLUMBING - GAS PRESSURE TEST BSTEVENS Approved IVRS - Inspection 0000*
03/23/2004 PLUMBING - INTERMEDIATE BSTEVENS Approved IVRS - Inspection 0000*
03/23/2004 ELECTRIC - SERVICE UPGRADE BSTEVENS Approved IVRS - Inspection 0000*
03/24/2004 TEP CLEARANCE - AM SREEVES Approved
04/29/2004 MECHANICAL - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*
04/29/2004 ELECTRIC - INTERMEDIATE RFREIDIN Approved IVRS - Inspection :*/ 1) AIR HANDLER IN ATTIC, HAS A U.L. LABEL MARK THE SPACE NEXT TO THE HEAT STRIP THAT'S INSIDE 2) YOU NEED A ACCESS HOLE TO SERVICE THE UNIT, ALSO A WORKING PLATFORM AND WALK WAY IF THE ACCESS HOLE IS NOT WITHIN WORKING DISTANCE OF THE UNIT, FRAMING MUST BE STRONG ENOUGH TO SUPPORT A LIVE LOAD 3) YOU NEED AN OVER FLOW PAN AND SECONDARY DRAIN TO OUTSIDE 4) YOU WILL NEED A DISCONNECT, FUSE PROTECTION THEIR OR AT SERVICE 5) WHEN LABEL IS MARKED CIRCUIT AMPACITY AND FUSE SIZE CAN BE DETERMINED 6) BLOCK AROUND YOUR MECH DUCT OPENINGS IN EACH ROOM AT CEILING 7) PLAN CALLS FOR ALL EXHAUST FAN IN BATHROOM 8) YOU NEED TO ADDRESS MANU FRAMING ITEMS, INCLUDING THE EXTRA WEIGHT OF ATTIC UNIT MAINTENCE LIVE LOAD EXT. 9) YOU HAVE A GALVANIZED 1" PIPE TAPPED INTO SEWER VENT VENTS OPEN TO ATTIC 10) NO ELECTRIC PAGE IN PLAN SET 11) RANGE HOOD/EXHAUST ?