Permit: T03CM05294
Permit Details
Apply Date:
11/06/2003
Applicant:
N/A
Description:
NEW:DUPLEX
Contractors:
- APOLLO ENTERPRISES L L C
Permit Reviews
Permit Number - T03CM05294
Permit Status: Final
Permit Description: NEW:DUPLEX
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/06/2004 | RESUBMITTAL | 01/23/2004 | COMPLETED |
| 01/23/2004 | RESUBMITTAL | 01/28/2004 | COMPLETED |
| 07/26/2004 | REVISION | 07/27/2004 | COMPLETED |
| 08/10/2004 | REVISION | 08/17/2004 | COMPLETED |
| 08/17/2004 | REVISION | 09/23/2004 | COMPLETED |
| 11/06/2003 | 3RD PARTY REVIEW-RESIDENTIAL | 11/06/2003 | COMPLETED |
| 12/02/2004 | RESUBMITTAL | 12/14/2004 | COMPLETED |
| 12/11/2003 | RESUBMITTAL | 12/16/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM05294
Permit Status: Final
Permit Description: NEW:DUPLEX
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/06/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T03CM05294
Permit Description: NEW:DUPLEX
Total Completed Inspections - 26
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/05/2004 | PLUMBING - ROUGH, SOIL | JSTANLEY | Approved | IVRS - Inspection 0000*/ 1) TEST OK 2) WRAP ABS IN SLAB |
| 02/09/2004 | BUILDING PRE-SLAB | HLEYVA | Approved | IVRS - Inspection 0000* |
| 03/23/2004 | ROOF NAILING | HLEYVA | Approved | IVRS - Inspection :* |
| 03/30/2004 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 03/30/2004 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* PENDING OTHER TRADES APPROVALS |
| 04/02/2004 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 04/21/2004 | STUCCO MESH | AQUIROZ | Approved | IVRS - Inspection :* |
| 04/22/2004 | PLUMBING - GAS PRESSURE TEST | JSTANLEY | Approved | |
| 04/22/2004 | PLUMBING - INTERMEDIATE | JSTANLEY | Approved | |
| 05/04/2004 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection : See detailed listing on site.| 999*/ 1) EXCLUDES 2ND LAYER |
| 06/23/2004 | PLUMBING - SEWER HCS CONNECT | JSTANLEY | Approved | IVRS - Inspection :* |
| 07/09/2004 | ELECTRIC - TEMPORARY POLE | RHOLLAND | Approved | IVRS - Inspection :* |
| 07/13/2004 | ELECTRIC - CABLE DROP | RHOLLAND | Approved | IVRS - Inspection :*/ 1) OK CABLE DROP 2) NEED ADDRESS LABEL |
| 07/22/2004 | ELECTRIC - TEMPORARY SERVICE | RSUBA | Approved | IVRS - Inspection :* |
| 07/23/2004 | TEP CLEARANCE - AM | JKOZUCH | Approved | ECO UNIT 2 ONLY |
| 12/22/2004 | U VALUE FOR WINDOW | BSTEVENS | Approved | IVRS - Inspection :* |
| 03/07/2005 | PLUMBING - YARD WTR LINE/TEST | JSTANLEY | Approved | |
| 03/07/2005 | PLUMBING - FINAL | JSTANLEY | Approved | IVRS - Inspection :* FINAL OK STOI PLUMBER TO CAULK ALL FIXTURES. LAST INSP. ON JOB PLEASE PROVIDE GAS CARD. |
| 03/07/2005 | OUTDOOR LIGHTING FINAL | RMAJUTA | Approved | IVRS - Inspection :* |
| 03/09/2005 | ELECTRIC - FINAL | RMAJUTA | Approved | IVRS - Inspection :* APPROVED. |
| 03/10/2005 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* APPROVED OK FOR FINAL |
| 03/11/2005 | EXCAVATION/LAYOUT REBAR & ZON | BSTEVENS | Approved | IVRS - Inspection :* |
| 03/17/2005 | REINFORCED MASONRY PRE-GROUT | AQUIROZ | Approved | |
| 03/17/2005 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection :* |
| 03/17/2005 | EXT METAL CLIPS/EXT SHEATHING | AQUIROZ | Approved | IVRS - Inspection :* |
| 09/15/2005 | PERMIT FINALED | LJACKSON | Approved |