Permit: T03CM03894
Permit Details
Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
1313 W SAINT MARYS RD
Address NEW:
1313 W SAINT MARYS RD
Apply Date:
08/06/2003
Applicant:
N/A
Description:
TI:BAKERY
Contractors:
- LUGO S WIRING
- LANG CONSTRUCTION INC , W J
Permit Reviews
Permit Number - T03CM03894
Permit Status: C of o
Permit Description: TI:BAKERY
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/06/2003 | PLANS OK TO SUBMIT - 3RD PARTY | 08/11/2003 | COMPLETED |
| 08/12/2003 | 3RD PARTY REVIEW-COMMERCIAL TI | 09/03/2003 | COMPLETED |
| 09/10/2003 | 3RD PARTY REVIEW-COMMERCIAL TI | 09/24/2003 | COMPLETED |
| 10/15/2003 | 3RD PARTY REVIEW-REVISION/OTHER | 10/23/2003 | COMPLETED |
| 12/01/2003 | 3RD PARTY REVIEW-REVISION/OTHER | 12/08/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM03894
Permit Status: C of o
Permit Description: TI:BAKERY
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/06/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T03CM03894
Permit Description: TI:BAKERY
Total Completed Inspections - 23
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/29/2003 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection 0000*/ 1) WALLS ROUGHED-IN WITH EMT AND STEEL BOXES |
| 09/29/2003 | FRAMING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 10/09/2003 | FIRE SPKLR - FINAL | JEGAN | Approved | IVRS - Inspection 0000*/ 1) STILL NEED C OF O FINAL. NEED PLAN/PERMIT FOR HOOD KITCHEN SYSTEM |
| 10/24/2003 | PLUMBING - GAS PRESS TEST FNL | RMYERS | Approved | IVRS - Inspection 0000* |
| 10/24/2003 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection 0000* |
| 10/24/2003 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection 0000* |
| 10/24/2003 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000*/ 1) ABS DWV THRU ROOF OK. 2) COPPER OK. 3) 60 LB GAS TEST OK. 4) GREASE TRAP OK. 5) OK TO COVER ALL AREAS. |
| 10/24/2003 | ELECTRIC - ABOVE CEILING | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 10/27/2003 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 11/14/2003 | BUILDING ABOVE CEILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 11/17/2003 | RIGHT OF WAY - FINAL | MOTERO | Approved | |
| 11/17/2003 | ENGINEERING - FINAL | JSALINE | Approved | C OF O APPROVED. |
| 11/17/2003 | FIRE - FINAL | JEGAN | Approved | IVRS - Inspection 0000* |
| 11/18/2003 | FIRE - KITCHEN EXH HOOD FINAL | LLAKEY | Approved | |
| 11/21/2003 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection 0000*/ 1) PLBG FINAL OK. 2) OK FOR C OF O PENDING ANY OTHER INSP. 3) LAST INSP. TO LEAVE GAS CARD. |
| 12/08/2003 | MECHANICAL - HOOD SYSTEMS | CWILLIAM | Approved | |
| 12/08/2003 | MECHANICAL - HOODS | CWILLIAM | Approved | |
| 12/08/2003 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | |
| 12/09/2003 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 12/09/2003 | ELECTRIC - FINAL | MCAPISTR | Approved | IVRS - Inspection 0000*/ 1) ACCEPT THE INSTALLATION OF THE SERVICE DISCONNECTS AND WIRNG EXTENSIONS TO PROCESS MACHINERY AS INSTALLED |
| 12/23/2003 | SIGN - FINAL | JYBARRA | Approved | |
| 12/23/2003 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 12/24/2003 | PERMIT FINALED | AQUIROZ | Approved |