Description:
ADDITION:GARAGE/WORKSHOP T03VL00027
Permit Reviews
Permit Number - T03CM03697
Permit Status: Expired
Permit Description: ADDITION:GARAGE/WORKSHOP T03VL00027
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
07/24/2003 | RESIDENTIAL BLDG/ZONING/ENGINE | 09/05/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM03697
Permit Status: Expired
Permit Description: ADDITION:GARAGE/WORKSHOP T03VL00027
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
07/24/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T03CM03697
Permite Description: ADDITION:GARAGE/WORKSHOP T03VL00027
Total Outstanding Inspections - 8
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
FRAMING | N/A | Not Inspected | ||
03/01/2004 | EXCAVATION/LAYOUT REBAR & ZON | N/A | Denied | IVRS - Inspection 0999*/ 1) EXPOSE FOOTING ON STRUCTURE TO PROVIDE DEPTH AND WIDTH OF FOUNDATION 2) STUCCO ONE COAT SYSTEM REQUIRES WEEP SCREED AT BOTTOM 3) EXPOSE 3' X 3' SECTION OF STUCCO LATH 4) EXPOSE HD5A HOLDOWNS 5) BRACED WALL PANEL NOT INSTALLED 6) OVER SPANNED 2 X 6 RAFTERS MUST BE SPACED AT 12" ON CENTER 7) BEAM AT GARAGE MID POINT NOT PER PLAN 8) HEADERS MUST BEAR ON TRIMMERS 9) PROVIDE PROOF OF REINFORCING STEEL 1) 8/A3 NOT COMPLIED WITH 11) EXPOSE ALL HEADER/ POST AND BEAM CONNECTIONS 12) EXPOSE ALL ANCHOR BOLTS 13) UNTREATED WOOD CANNOT BE IN CONTACT WITH CONCRETE 14) STRUCTURE NOT BUILT PER PLAN 15) STOPPED INSPECTION |
03/01/2004 | BUILDING PRE-SLAB | N/A | Denied | IVRS - Inspection 0999* |
03/01/2004 | REINFORCED MASONRY PRE-GROUT | N/A | Denied | IVRS - Inspection 0999* |
03/01/2004 | EXT METAL CLIPS/EXT SHEATHING | N/A | Denied | IVRS - Inspection 0999* |
03/01/2004 | ROOF NAILING | N/A | Denied | IVRS - Inspection 0999* |
03/01/2004 | STUCCO MESH | N/A | Denied | IVRS - Inspection 0999* |
03/01/2004 | BUILDING - FINAL | N/A | Denied | IVRS - Inspection 0999* |