Permit: T03CM03393
Permit Details
Status:
C of o
Type:
MULTI FAMILY NEW
Address:
6795 E CALLE LA PAZ 02
Address NEW:
6795 E CALLE LA PAZ 02
Apply Date:
07/11/2003
Applicant:
METRO PERMIT EXPRESS, INC
Description:
NEW:APARTMENTS
Architects:
- ACORN, KIM BRIAN
Contractors:
- PREFERRED APARTMENT BUILDERS INC
Permit Reviews
Permit Number - T03CM03393
Permit Status: C of o
Permit Description: NEW:APARTMENTS
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/08/2004 | 3RD PARTY REVIEW-COMMERCIAL | 04/26/2004 | COMPLETED |
| 04/23/2004 | POST 3RD PARTY REVIEW | 06/11/2004 | COMPLETED |
| 06/11/2004 | RESUBMITTAL | 06/18/2004 | COMPLETED |
| 07/11/2003 | PLANS OK TO SUBMIT - 3RD PARTY | 07/15/2003 | COMPLETED |
| 07/17/2003 | 3RD PARTY REVIEW-COMMERCIAL | 08/12/2003 | COMPLETED |
| 07/20/2004 | 3RD PARTY REVIEW-REVISION/OTHER | 07/30/2004 | COMPLETED |
| 08/20/2004 | 3RD PARTY REVIEW-REVISION/OTHER | 08/23/2004 | COMPLETED |
| 08/30/2004 | 3RD PARTY REVIEW-REVISION/OTHER | 08/31/2004 | COMPLETED |
| 11/09/2004 | 3RD PARTY REVIEW-REVISION/OTHER | 11/16/2004 | COMPLETED |
| 12/08/2004 | 3RD PARTY REVIEW-REVISION/OTHER | 12/09/2004 | COMPLETED |
| 12/15/2004 | 3RD PARTY REVIEW-REVISION/OTHER | 12/15/2004 | COMPLETED |
| 12/17/2003 | 3RD PARTY REVIEW-COMMERCIAL | 12/29/2003 | COMPLETED |
| 12/27/2004 | 3RD PARTY REVIEW-REVISION/OTHER | 01/05/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM03393
Permit Status: C of o
Permit Description: NEW:APARTMENTS
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 07/11/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T03CM03393
Permit Description: NEW:APARTMENTS
Total Completed Inspections - 42
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/04/2004 | ELECTRIC - UFER | RHOLLAND | Approved | IVRS - Inspection :OK 2-#3/0 TO REBAR - OK TO POUR |
| 08/04/2004 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :*/ 1) APPROVED PLAN ON SITE |
| 08/04/2004 | BUILDING PRE-SLAB | RSUBA | Approved | IVRS - Inspection :* |
| 08/04/2004 | EXCAVATION/LAYOUT REBAR & ZON | RSUBA | Approved | IVRS - Inspection :* |
| 08/09/2004 | PLUMBING - FINAL | JSTANLEY | Approved | IVRS - Inspection :*FINAL OK CORRECTIONS MADE CALL GAS CO 889-1888 CARD AT METER SET. |
| 08/11/2004 | PLUMBING - YARD WTR LINE/TEST | JSTANLEY | Approved | IVRS - Inspection :*/ 1) STUB INSIDE |
| 08/25/2004 | FIRE SPKLR - UG, PIPING, HYDRO | LLAKEY | Approved | |
| 09/20/2004 | STUCCO MESH | RSUBA | Approved | IVRS - Inspection :*/ 1) PARTIAL AT ELECTRIC SERVICE |
| 10/07/2004 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection :*/1)TIE IN AT SITE SEWER OK TO COVER 2)SUBJECT TO CERTIFICATION OF PRIVATE SEWER |
| 10/14/2004 | ROOF NAILING | RSUBA | Approved | IVRS - Inspection :* |
| 10/22/2004 | FRAMING | RSUBA | Approved | IVRS - Inspection :* |
| 12/03/2004 | U VALUE FOR WINDOW | HLEYVA | Approved | IVRS - Inspection :* |
| 12/03/2004 | PLUMBING - ROOF DRAINS | JSTANLEY | Approved | IVRS - Inspection :* |
| 12/07/2004 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :*/NO ABOVE CEILING ON THIS BLDG. OK FOR PRE SHEET ROCK |
| 12/10/2004 | PLUMBING - INTERMEDIATE | JSTANLEY | Approved | IVRS - Inspection :*/TEST ON WASTE & VENTS ONLY. NEED TO COMPLETE WATER & INSTALL TUBE |
| 12/10/2004 | PLUMBING - ABOVE CEILING | JSTANLEY | Approved | IVRS - Inspection :* |
| 12/12/2004 | EXT METAL CLIPS/EXT SHEATHING | HLEYVA | Approved | IVRS - Inspection :* 1) PENDING CHANGE RE: CLIPS AT EXTERIOR OPENINGS |
| 02/16/2005 | BUILDING ABOVE CEILING | BSTEVENS | Approved | IVRS - Inspection :* APPROVED |
| 03/01/2005 | SHEET ROCK NAILING | BSTEVENS | Approved | IVRS - Inspection :* |
| 03/15/2005 | ELECTRIC - CABLE DROP | RHOLLAND | Approved | IVRS - Inspection :* OK CABLE DROP ONLY NO UNITS |
| 04/21/2005 | ELECTRIC - UNDERGROUND | RSUBA | Approved | IVRS - Inspection :* |
| 05/11/2005 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* OK FOR FINAL C OF O |
| 05/11/2005 | ELECTRIC - TEMP POWER FOR TEST | RHOLLAND | Approved | IVRS - Inspection :* 1) OK 2205 TEMP POWER TEST |
| 05/24/2005 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
| 05/26/2005 | RIGHT OF WAY - FINAL | PWHIDDON | Approved | PER PH CALL |
| 05/26/2005 | ENGINEERING - FINAL | JBRUCKME | Approved | OK FOR TEMPORARY C OF O. 1. PROVIDE ADDITIONAL SCUPPERS WHERE NEEDED AS INDICATED BY WHITE PAINT ON SIDEWALK, ALSO PROVIDE DRAINAGE SWALES TO SCUPPERS. 2. BARRICADE ALL AREAS WHERE ON-GOING CONSTRUCTION ACTIVITY IS OCCURRING ADJACENT TO THIS BUILDING. KEEP THE FENCE UP TO PREVENT PEDESTRIAN TRAFFIC. 3. PROVIDE RAIN GUTTERS TO PREVENT STORMWATER DRAINAGE ONTO STAIRWAYS AND PEDESTRIAN WALKWAYS. PER C.O.T. DEVELOPMENT STANDARD No,2-08.0 |
| 05/26/2005 | OUTDOOR LIGHTING FINAL | RHOLLAND | Approved | IVRS - Inspection :* 1) OK OUTDOOR LIGHTING |
| 05/26/2005 | FIRE - FINAL | LTHOMAS | Approved | |
| 05/26/2005 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
| 05/26/2005 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
| 05/26/2005 | FIRE SPKLR - UG PIPING FLUSH | LTHOMAS | Approved | |
| 06/17/2005 | TEP CLEARANCE - AM | RCAMACHO | Approved | ECO # 2205 BOND POSTED |
| 06/20/2005 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | PER MECH FINAL |
| 06/20/2005 | ELECTRIC - FINAL | RHOLLAND | Approved | PER INSP PAPER |
| 06/20/2005 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | PER INSP PAPER |
| 06/20/2005 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | PER INSP PAPER |
| 06/20/2005 | PLUMBING - GAS PRESS TEST FNL | JSTANLEY | Approved | PER PLUMBING FINAL |
| 06/20/2005 | PLUMBING - GAS PRESSURE TEST | JSTANLEY | Approved | PER PLUMBING FINAL |
| 06/20/2005 | BUILDING - FINAL | BSTEVENS | Approved | PER INSP PAPER |
| 08/10/2005 | NPPO - FINAL | ACONNOR | Approved | |
| 08/10/2005 | LANDSCAPE - FINAL | ACONNOR | Approved | |
| 04/12/2006 | PERMIT FINALED | LJACKSON | Approved |