Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY NEW
Address:
5805 S 6TH AV
Apply Date:
06/20/2003
Applicant:
FIMBRES GILBERT
Description:
RENEW PERMIT:SFR T01CM00017

Permit Reviews

Permit Number - T03CM03014
Permit Status: Final
Permit Description: RENEW PERMIT:SFR T01CM00017
Start Date Submittal Complete Date Status  
06/20/2003 OTHER 06/20/2003 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T03CM03014
Permit Status: Final
Permit Description: RENEW PERMIT:SFR T01CM00017
Total Outstanding Activity Conditions - 1
Date Name
06/20/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T03CM03014
Permit Description: RENEW PERMIT:SFR T01CM00017
Total Completed Inspections - 2
Date Description Inspector Results Comments
07/25/2003 BUILDING - FINAL ROHAVER Approved IVRS - Inspection 0999*/ 1) POST ADDRESS NUMBERS ON HOUSE VISIBLE FROM 6TH AVE. 2) KITCHEN ELECTRIC 2 HAVE 2-20 AMP SMALL APPLIANCE CIRCUIT 3) INSTALL ELECTRIC FIXTURES 4) OUTLET MISSING KITCHEN WALLS PER PLAN 5) NEED INSULATION CERTIFICATE 6) WATER HEATER ELECTRIC TO BE IN FLEX, CONDUIT 7) FURNACE GAS FLEX CANNOT GO THROUGH CABINET 8) ELECTRIC FURNACE TO HAVE ROMEX CONNECTOR AT CABINET PENETRATION 9) FURNACE COMBUSTIBLE AIR NOT TO CODE 10) REPLACE SWITCH PLATE BATHROOM 11) INSTAL ANTI-SIPHON HOSE BIBS 12) SEAL ALL PENECTRATIONS EXTERIOR WALLS 13) INSTALL CAP EXTERIOR FURNACE FLUE PIPE 14) CUT SEWER CLEANOUT TO GRADE 15) COMPLETE GRADING TO SLOPE AWAY FROM HOUSE 16) INSTALL GABLE END VENTS PER PLAN 17) INSTALL VENTED FREEZE BOARDS PER PLAN 18) NEED TO ADD ELECTRIC, PLUMBING, MECHANICAL AND GAS TO RENEWED PERMIT CARD
06/18/2004 PERMIT FINALED JRIVA Approved