Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T03CM02822
Permit Details
Apply Date:
06/09/2003
Applicant:
SKYLINE HOMES
Description:
NEW:SFR
Contractors:
- SKYLINE HOMES
Permit Reviews
Permit Number - T03CM02822
Permit Status: C of o
Permit Description: NEW:SFR
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/02/2004 | REVISION | 04/02/2004 | COMPLETED |
06/09/2003 | PLANS OK TO SUBMIT - RES | 06/10/2003 | COMPLETED |
06/10/2003 | RESIDENTIAL BLDG/ZONING/ENGINE/WWM | 07/18/2003 | COMPLETED |
08/07/2003 | RESUBMITTAL | 09/09/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM02822
Permit Status: C of o
Permit Description: NEW:SFR
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
06/09/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T03CM02822
Permit Description: NEW:SFR
Total Completed Inspections - 24
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/03/2003 | PLUMBING - SEWER HCS CONNECT | HCAMPBEL | Approved | |
10/03/2003 | PLUMBING - YARD WTR LINE/TEST | HCAMPBEL | Approved | |
10/03/2003 | PLUMBING - ROUGH, SOIL | HCAMPBEL | Approved | IVRS - Inspection 0000* |
12/19/2003 | ELECTRIC - TEMPORARY SERVICE | FGREER | Approved | |
12/22/2003 | ELECTRIC - CABLE DROP | FGREER | Approved | IVRS - Inspection 0000* |
12/29/2003 | ROOF NAILING | HCAMPBEL | Approved | IVRS - Inspection 0000* |
12/29/2003 | EXT METAL CLIPS/EXT SHEATHING | HCAMPBEL | Approved | IVRS - Inspection 0000* |
12/31/2003 | PLUMBING - GAS PRESSURE TEST | HCAMPBEL | Approved | IVRS - Inspection 0999* |
12/31/2003 | PLUMBING - INTERMEDIATE | HCAMPBEL | Approved | IVRS - Inspection 0999* |
12/31/2003 | ELECTRIC - INTERMEDIATE | HCAMPBEL | Approved | IVRS - Inspection 0999* |
12/31/2003 | ELECTRIC - UFER | HCAMPBEL | Approved | IVRS - Inspection 0999* |
12/31/2003 | FRAMING | HCAMPBEL | Approved | IVRS - Inspection 0999*/ 1) REPAIR STUD NEAR FP WITH BETTER METHOD 2) INSTALL FIRE STOP AT LIVING ROOM (EAST) MASTER BEDROOM 3) COMPLETE STUCCO MESH 4) NAIL PLATE CONDUCTORS WITHIN 1 1/4" OF STUD EDGES 5) BLOCK 4 GANG BOXES 6) TEST WASTE 7) NAIL PLATE WATER IN LAUNDRY, WASTE IN KITCHEN, WATER AT NORTH WATER HEATER 8) NOTE: SEE ITEMS ON PAGE. TWO CIRCLED FROM PREVIOUS INSPECTION 9) NOTES: REVISION ON FOUNDATION AND FRAMING AT PORCH NEED SUBMITTAL FOR APPROVAL BY CITY OF TUCSON 10) SPECIAL INSPECTION ALSO NEEDED FOR PIER FOOTINGS AT PATIO |
12/31/2003 | BUILDING PRE-SLAB | HCAMPBEL | Approved | IVRS - Inspection 0999* |
12/31/2003 | STEM WALL/RETAINING WALL | HCAMPBEL | Approved | IVRS - Inspection 0999* |
12/31/2003 | EXCAVATION/LAYOUT REBAR & ZON | HCAMPBEL | Approved | IVRS - Inspection 0999* |
01/14/2004 | STUCCO MESH | HCAMPBEL | Approved | IVRS - Inspection 0000* |
04/05/2004 | PERMIT FINALED | FGREER | Approved | |
04/05/2004 | MECHANICAL - FINAL | FGREER | Approved | IVRS - Inspection 0000* |
04/05/2004 | PLUMBING - FINAL | FGREER | Approved | IVRS - Inspection 0000* |
04/05/2004 | ELECTRIC - FINAL | FGREER | Approved | IVRS - Inspection 0000* |
04/05/2004 | BUILDING - FINAL | FGREER | Approved | IVRS - Inspection 0000* |
04/05/2004 | SHEET ROCK NAILING | FGREER | Approved | |
04/05/2004 | U VALUE FOR WINDOW | FGREER | Approved | |
04/06/2004 | TEP CLEARANCE - AM | JKOZUCH | Approved |