Permit: T03CM02553
Permit Details
Status:
Final
Type:
DUPLEX NEW
Address:
426 W PENNSYLVANIA DR #01
Address NEW:
426 W PENNSYLVANIA DR #01
Apply Date:
05/27/2003
Applicant:
DELGADO MANNY
Description:
DUPLEX:NEW
Contractors:
- IGUANA CONSTRUCTION CO INC ,
Permit Reviews
Permit Number - T03CM02553
Permit Status: Final
Permit Description: DUPLEX:NEW
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/27/2003 | PLANS OK TO SUBMIT - RES | 05/27/2003 | COMPLETED |
| 05/27/2003 | RESIDENTIAL BLDG/WWM | 06/25/2003 | COMPLETED |
| 09/16/2003 | REVISION | 09/16/2003 | COMPLETED |
| 10/10/2003 | REVISION | 10/10/2003 | COMPLETED |
| 10/27/2003 | REVISION | 10/27/2003 | COMPLETED |
| 11/13/2003 | REVISION | 11/13/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM02553
Permit Status: Final
Permit Description: DUPLEX:NEW
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/27/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T03CM02553
Permit Description: DUPLEX:NEW
Total Completed Inspections - 23
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/19/2003 | ELECTRIC - UFER | RMAJUTA | Approved | IVRS - Inspection 0000*/ PLAN ON FENCE WEST SIDE. #4 COPPER TO REBAR. |
| 10/01/2003 | STEM WALL/RETAINING WALL | AMATHIES | Approved | IVRS - Inspection 0000* |
| 10/13/2003 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection 0000* |
| 10/15/2003 | PLUMBING - SEWER HCS CONNECT | TRINIVJR | Approved | IVRS - Inspection 0000*/ 1) SOIL WATER TEST IS OK. 2) OK TO BACKFILL TRENCH. |
| 10/27/2003 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection 0000* |
| 11/10/2003 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 11/10/2003 | EXT METAL CLIPS/EXT SHEATHING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 11/21/2003 | U VALUE FOR WINDOW | AMATHIES | Approved | IVRS - Inspection 0000* |
| 11/21/2003 | STUCCO MESH | AMATHIES | Approved | IVRS - Inspection 0000* |
| 11/21/2003 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection 0000* |
| 11/24/2003 | ELECTRIC - TEMPORARY SERVICE | RMAJUTA | Approved | IVRS - Inspection 0000*SENT TO TEP ON 1125AM |
| 11/24/2003 | ELECTRIC - CABLE DROP | RMAJUTA | Approved | IVRS - Inspection 0000*/ 1) OK TO CLEAR #1 AND #2 2) SENT TO TEP ON 1125AM |
| 12/08/2003 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 12/08/2003 | PLUMBING - YARD WTR LINE/TEST | TRINIVJR | Approved | IVRS - Inspection 0000* |
| 12/08/2003 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection 0000* |
| 12/09/2003 | FRAMING | AMATHIES | Approved | IVRS - Inspection 0000* AT PARTY WALL (1 HR) REMOVE NAILERS AND LADDER BLOCKING SO WALL CAN BE COVERED WITH DRYWALL WITHOUT ANY PENETRATIONS. |
| 12/15/2003 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection 0000*/ 1) SOIL WATER TEST IS OK. 2) OVERHEAD WTR DISTRIBUTION IS OK. 3) OK FOR DRYWALL UPON BLDG INSPECTORS APPROVAL. |
| 12/31/2003 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 02/09/2004 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 02/09/2004 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection 0000* |
| 02/12/2004 | PERMIT FINALED | DSANTACR | Approved | |
| 02/12/2004 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection 0000*/ 1) PLBG FINAL IS OK. 2) OK FOR C OF O. |
| 02/12/2004 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection 0000* |