Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Address:
701 W CALLE MILU
Address NEW:
701 W CALLE MILU
Apply Date:
05/08/2003
Applicant:
LARA JOSE JUAN C & MARIA O JT/RS
Description:
NEW:SFR R1 Add cooktop w/ 1 1/4" gas main, add 8" CMU, open two doors, move W/H from bonus room to porch and add nitch.

Permit Reviews

Permit Number - T03CM02265
Permit Status: C of o
Permit Description: NEW:SFR R1 Add cooktop w/ 1 1/4" gas main, add 8" CMU, open two doors, move W/H from bonus room to porch and add nitch.
Start Date Submittal Complete Date Status  
04/26/2006 REVISION - WALK THRU 04/26/2006 COMPLETED Review Details
05/08/2003 PLANS OK TO SUBMIT - RES 06/06/2003 COMPLETED Review Details
06/06/2003 OTHER 07/11/2003 COMPLETED Review Details
08/18/2003 RESUBMITTAL 09/09/2003 COMPLETED Review Details
09/16/2003 RESUBMITTAL 10/21/2003 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T03CM02265
Permit Status: C of o
Permit Description: NEW:SFR R1 Add cooktop w/ 1 1/4" gas main, add 8" CMU, open two doors, move W/H from bonus room to porch and add nitch.
Total Outstanding Activity Conditions - 1
Date Name
05/08/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T03CM02265
Permit Description: NEW:SFR R1 Add cooktop w/ 1 1/4" gas main, add 8" CMU, open two doors, move W/H from bonus room to porch and add nitch.
Total Completed Inspections - 25
Date Description Inspector Results Comments
11/14/2003 ELECTRIC - UFER JRIVA Approved
11/14/2003 EXCAVATION/LAYOUT REBAR & ZON JRIVA Approved IVRS - Inspection 0000*
03/12/2004 STEM WALL/RETAINING WALL JRIVA Approved IVRS - Inspection 0000*
05/13/2004 PLUMBING - SEWER HCS CONNECT JRIVA Approved IVRS - Inspection :*
05/13/2004 PLUMBING - ROUGH, SOIL JRIVA Approved IVRS - Inspection :*
06/03/2004 BUILDING PRE-SLAB JRIVA Approved IVRS - Inspection :*
12/23/2004 REINFORCED MASONRY PRE-GROUT JRIVA Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) NO PLANS/PERMIT ON SITE
2) PART OF SECOND LIFT WAS GROUTED WITHOUT INSPECTION NOW THERE IS NO OVERLAP ON VERTICAL REBAR. TAKE WALL DOWN TO EXPOSE 20" OF OVERLAP OF FIRST LIFT REBAR
3) BOND BEAM BLOCK PUT IN UPSIDE DOWN. YOU MUST HAVE 1 1/2" OF CONCRETE ABOVE BOND BEAM REBAR
4) CANNOT SEE HORIZONTAL DURA WALL WIRE IN WALL. PROVIDE PROOF OF INSTALLATION
10/11/2005 ROOF NAILING HPEDROZA Approved IVRS - Inspection :*
10/13/2005 FRAMING HPEDROZA Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) FRAMING WILL BE INSPECTED WHEN ALL TRADES ARE COMPLETE FOR INTERMEDIATES, I.E... PLUMBING, MECHANICAL, ELECTRICAL AND GAS PRESSURE TEST
10/19/2005 ELECTRIC - TEMPORARY SERVICE HPEDROZA Approved IVRS - Inspection :*ECO
10/19/2005 ELECTRIC - CABLE DROP HPEDROZA Approved IVRS - Inspection :*
10/20/2005 TEP CLEARANCE - AM JKOZUCH Approved
05/01/2006 PLUMBING - GAS PRESSURE TEST CTREVILL Approved IVRS - Inspection :*
05/01/2006 PLUMBING - INTERMEDIATE CTREVILL Approved IVRS - Inspection :*
05/03/2006 ELECTRIC - INTERMEDIATE CTREVILL Approved IVRS - Inspection :*
05/03/2006 MECHANICAL - INTERMEDIATE CTREVILL Approved IVRS - Inspection :*
07/13/2006 SHEET ROCK NAILING CTREVILL Approved IVRS - Inspection :*
03/30/2007 U VALUE FOR WINDOW CTREVILL Approved
03/30/2007 PLUMBING - GAS PRESS TEST FNL CTREVILL Approved
03/30/2007 PLUMBING - YARD WTR LINE/TEST CTREVILL Approved
03/30/2007 BUILDING - FINAL CTREVILL Approved IVRS - Inspection :*
1) NO CERTS AVAILABLE HOMEOWNER/BUILDER
03/30/2007 MECHANICAL - FINAL CTREVILL Approved IVRS - Inspection :*
03/30/2007 PLUMBING - FINAL CTREVILL Approved IVRS - Inspection :*
03/30/2007 ELECTRIC - FINAL CTREVILL Approved IVRS - Inspection :*
04/02/2007 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW