Permit: T03CM02032
Permit Details
Status:
C of o
Type:
SINGLE FAMILY NEW
Address:
145 W CORONA RD #02
Address NEW:
145 W CORONA RD #02
Apply Date:
04/25/2003
Applicant:
DIANA ORTIZ
Description:
NEW:SFR
Contractors:
- IRKA CONSTRUCTION L L C ,
Outstanding Activity Conditions
Permit Number - T03CM02032
Permit Status: C of o
Permit Description: NEW:SFR
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/25/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T03CM02032
Permit Description: NEW:SFR
Total Completed Inspections - 24
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/14/2003 | PLUMBING - ROUGH, SOIL | FGREER | Approved | IVRS - Inspection 0000* |
| 10/17/2003 | ELECTRIC - UFER | MTESTER | Approved | |
| 10/17/2003 | EXCAVATION/LAYOUT REBAR & ZON | MTESTER | Approved | IVRS - Inspection 0000* |
| 11/26/2003 | REINFORCED MASONRY PRE-GROUT | ROHAVER | Approved | IVRS - Inspection 0000* |
| 12/23/2003 | ELECTRIC - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection 0000* |
| 12/23/2003 | FRAMING | JRIVA | Approved | IVRS - Inspection 0999*/ no city approved engineering truss drawings on site. overbuild rafters require u-26 hangers at ridge board and collars at 4'. fire block all furred out ares. |
| 12/23/2003 | ROOF NAILING | JRIVA | Approved | IVRS - Inspection 0000* |
| 12/23/2003 | EXT METAL CLIPS/EXT SHEATHING | JRIVA | Approved | IVRS - Inspection 0000* |
| 12/23/2003 | BUILDING PRE-SLAB | JRIVA | Approved | IVRS - Inspection 0000* |
| 12/23/2003 | STEM WALL/RETAINING WALL | JRIVA | Approved | IVRS - Inspection 0000* |
| 01/08/2004 | PLUMBING - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection 0000* |
| 01/13/2004 | MECHANICAL - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection 0000* |
| 01/22/2004 | SHEET ROCK NAILING | ROHAVER | Approved | IVRS - Inspection 0000* |
| 01/30/2004 | PLUMBING - SEWER HCS CONNECT | ROHAVER | Approved | IVRS - Inspection 0000* |
| 06/17/2004 | PLUMBING - YARD WTR LINE/TEST | FGREER | Approved | IVRS - Inspection :* |
| 06/17/2004 | ELECTRIC - TEMPORARY SERVICE | FGREER | Approved | IVRS - Inspection :* |
| 06/17/2004 | ELECTRIC - CABLE DROP | FGREER | Approved | IVRS - Inspection :* |
| 06/18/2004 | TEP CLEARANCE - AM | JKOZUCH | Approved | |
| 08/13/2004 | PERMIT FINALED | FGREER | Approved | |
| 08/13/2004 | U VALUE FOR WINDOW | FGREER | Approved | IVRS - Inspection :* |
| 08/13/2004 | MECHANICAL - FINAL | FGREER | Approved | IVRS - Inspection :* |
| 08/13/2004 | PLUMBING - FINAL | FGREER | Approved | IVRS - Inspection :* |
| 08/13/2004 | ELECTRIC - FINAL | FGREER | Approved | IVRS - Inspection :* |
| 08/13/2004 | BUILDING - FINAL | FGREER | Approved | IVRS - Inspection :* |