Permit: T03CM01967
Permit Details
Status:
Final
Type:
COMMERCIAL ALTERATION
Address:
1503 W SAINT MARYS RD
Address NEW:
1503 W SAINT MARYS RD
Apply Date:
04/23/2003
Applicant:
N/A
Description:
TI:RESTAURANT
Architects:
- LARRY CLICK
Contractors:
- CAYLOR CONSTRUCTION COMPANY , RO
Permit Reviews
Permit Number - T03CM01967
Permit Status: Final
Permit Description: TI:RESTAURANT
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/23/2003 | COMMERCIAL TI | 04/28/2003 | COMPLETED |
| 06/20/2003 | REVISION | 06/23/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM01967
Permit Status: Final
Permit Description: TI:RESTAURANT
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/23/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T03CM01967
Permit Description: TI:RESTAURANT
Total Completed Inspections - 21
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/29/2003 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection 0000*ABS DWV UNDERGROUND THRU ROOF OK WATER TEST OK 2.) OK TO BACKFILL. |
| 05/07/2003 | FRAMING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 05/13/2003 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 05/13/2003 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 05/22/2003 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | IVRS - Inspection 0000*/PKG HEAT PUMP - AUX HEAT STRIP YES?/NO? MAX FUSE SIZE - 40 AMPS - NO STRIP UNIT FUSES/ 50 AMPS?? COMPLETE DATA PLATE!! ELECTRIC TO CONDENSERS - FREEZER, WALKIN - NOT COMPLETE. |
| 06/09/2003 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection 0000*/ 1) ABOVE CEILING-OK 2) PLEASE HAVE ALL REQUIRED INSPECTIONS APPROVED BEFORE CALLING FINAL. SEE NOTE #3 ABOVE |
| 06/11/2003 | ELECTRIC - ABOVE CEILING | RMAJUTA | Approved | IVRS - Inspection 0000*/ 1) CLOSE UP J-BOX ABOVE DOOR INTO BACK AREA AND BOX ABOVE REAR WALK IN |
| 06/11/2003 | BUILDING ABOVE CEILING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 06/12/2003 | PLUMBING - PROGRESS | RMYERS | Approved | IVRS - Inspection 0000* |
| 06/13/2003 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000*/ 1) CLOSET FLANGES OK |
| 06/16/2003 | FIRE - FINAL | JEGAN | Approved | IVRS - Inspection 0000* |
| 06/17/2003 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
| 06/24/2003 | ELECTRIC - FINAL | RMAJUTA | Approved | IVRS - Inspection 0000* |
| 06/25/2003 | RIGHT OF WAY - FINAL | MOTERO | Approved | |
| 06/25/2003 | NPPO - FINAL | PGILBERT | Approved | |
| 06/25/2003 | ENGINEERING - FINAL | DROBERTS | Approved | |
| 06/25/2003 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 06/25/2003 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection 0000*/ 1) PENDING APPROVAL OF OTHER TRADES |
| 06/30/2003 | PERMIT FINALED | AMATHIES | Approved | |
| 06/30/2003 | HEALTH DEPT - FINAL 724-7908 | JTERRELL | Approved | |
| 06/30/2003 | PLUMBING - FINAL | RMYERS | Approved | 1) SODA DISPENSOR AND ICE MAKER/STORAGE BIN DRAINS FALL UNDER 94 UPC 2) YOU NEED TO REVIEW SECTION ON INDIRECT WASTE PIPING 3) DRAINS MAY NOT BE COMBINED, USE APPROVED MATERIALS. INSTALL IN A WORKMANSHIP LIKE MANNER. CHANGES OF DIRECTION REQUIRE CLEANOUTS. MUST BE CORRECTLY TRAPPED-RUNNING TRAPS NOT APPROVED 4) ANCHOR AND SUPPORTED IN APPROVED MANNER REINSPECTED 3:00 PM, CORRECTIONS MADE. OK FOR C OF O PENDING ANY OTHER INSPECTIONS |