Permit: T03CM01578
Permit Details
Status:
Expired
Type:
SINGLE FAMILY ADDITION
Address:
1621 W BUCKEYE LN
Address NEW:
1621 W BUCKEYE LN
Apply Date:
03/31/2003
Applicant:
DIEHL RON
Description:
ADDITION:BATHROOM & REPAIRS:GENERAL T03VL00205
Contractors:
- BLUE LIGHT ELECTRIC L L C
Permit Reviews
Permit Number - T03CM01578
Permit Status: Expired
Permit Description: ADDITION:BATHROOM & REPAIRS:GENERAL T03VL00205
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/27/2005 | REVISION - WALK THRU | 01/28/2005 | COMPLETED |
| 02/10/2004 | REVISION | 02/12/2004 | COMPLETED |
| 03/31/2003 | RESIDENTIAL BLDG/ZONING/ENGINE/WWM | 03/31/2003 | COMPLETED |
| 03/31/2003 | OTHER | 04/30/2003 | COMPLETED |
| 05/06/2003 | RESUBMITTAL | 05/30/2003 | COMPLETED |
| 11/22/2004 | REVISION - WALK THRU | 11/23/2004 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM01578
Permit Status: Expired
Permit Description: ADDITION:BATHROOM & REPAIRS:GENERAL T03VL00205
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 03/31/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T03CM01578
Permite Description: ADDITION:BATHROOM & REPAIRS:GENERAL T03VL00205
Total Outstanding Inspections - 7
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| BUILDING - FINAL | N/A | Not Inspected | ||
| ELECTRIC - SERVICE UPGRADE | N/A | Not Inspected | ||
| ELECTRIC - FINAL | N/A | Not Inspected | ||
| PLUMBING - FINAL | N/A | Not Inspected | ||
| MECHANICAL - FINAL | N/A | Not Inspected | ||
| 01/18/2007 | PLUMBING - SEWER HCS CONNECT | N/A | Not ready for Inspection | IVRS - Inspection :* 1) INCOMPLETE |
| 01/31/2005 | PLUMBING - GAS PRESS TEST FNL | N/A | Not ready for Inspection | IVRS - Inspection :* NR |
Completed Inspections
Permit Status: Expired
Permit Number: T03CM01578
Permit Description: ADDITION:BATHROOM & REPAIRS:GENERAL T03VL00205
Total Completed Inspections - 10
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/17/2003 | SHEET ROCK NAILING | DQUINN | Approved | IVRS - Inspection 0999* |
| 09/17/2003 | ROOF NAILING | DQUINN | Approved | IVRS - Inspection 0999*/ 1) NEED PLAN/PERMIT ON SITE |
| 11/19/2003 | ELECTRIC - TEMPORARY SERVICE | HCAMPBEL | Approved | IVRS - Inspection 0000*SENT TO TEP ON 1120AM |
| 11/19/2003 | ELECTRIC - CABLE DROP | HCAMPBEL | Approved | IVRS - Inspection 0000*SENT TO TEP ON 1120AM |
| 03/15/2004 | ELECTRIC - INTERMEDIATE | HCAMPBEL | Approved | IVRS - Inspection 0000* |
| 11/02/2004 | FRAMING | ROHAVER | Approved | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NEED VERIFICATION ALL POST TO BEAM, POST TO CONCRETE CONNECTIONS; ALL BOTTOM PLATES TO CONCRETE, BEARING STUDS TO PLATES TOP AND BOTTOM; TOP PLATES TO BEAMS, BEAMS TO RAFTERS 2) FILL ALL NAIL HOLES IN A35'S ETC.. 3) STRAP ALL PLUMBING WITHIN 1 1/2" OF STUD; RAFTER FACE 4) STRAP ? ELECTRIC WITHIN 1 1/4" OF STUD-RAFTER FACE 5) WATER TEST DWV PIPING THROUGH ROOF 6) MUST COMPLETE ALL ELECTRIC, PLB, MECH GAS AS WELL AS FRAMING THEN RECALL FOR INSPECTION 7) PLAN CALLS FOR 2-2 X 10 EACH SIDE SKI LIGHTS 8) HEADERS NOT PER PLAN 9) HEADERS OVER WINDOWS INCORRECTLY INSTALLED 10) STRAP ALL HEADERS TO BEARING BELOW 11) WILL NEED TO REMOVE SHEETROCK, PLYWOOD, ETC.. TO INSPECT FRAMING 12) STOPPED INSPECTION |
| 01/31/2005 | PLUMBING - ROUGH, SOIL | ROHAVER | Approved | |
| 01/31/2005 | PLUMBING - GAS PRESSURE TEST | ROHAVER | Approved | IVRS - Inspection :* |
| 01/31/2005 | MECHANICAL - INTERMEDIATE | ROHAVER | Approved | IVRS - Inspection :* |
| 01/31/2005 | PLUMBING - INTERMEDIATE | ROHAVER | Approved | IVRS - Inspection :* |