Permit Details

Status:
Final
Type:
SINGLE FAMILY ALTERATION
Address NEW:
2917 E MALVERN ST
Apply Date:
03/14/2003
Applicant:
STERNER MATTHEW A & CONSTANCE C
Description:
REMOVE:SCREENED PORCH/ADDITION:STORAGE ROOM

Permit Reviews

Permit Number - T03CM01314
Permit Status: Final
Permit Description: REMOVE:SCREENED PORCH/ADDITION:STORAGE ROOM
Start Date Submittal Complete Date Status  
03/14/2003 RESIDENTIAL BLDG/ZONING/FLOOD-WALK THRU 04/04/2003 COMPLETED Review Details
11/20/2003 REVISION 11/21/2003 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T03CM01314
Permit Status: Final
Permit Description: REMOVE:SCREENED PORCH/ADDITION:STORAGE ROOM
Total Outstanding Activity Conditions - 1
Date Name
03/14/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T03CM01314
Permit Description: REMOVE:SCREENED PORCH/ADDITION:STORAGE ROOM
Total Completed Inspections - 9
Date Description Inspector Results Comments
10/24/2003 PERMIT FINALED ROHAVER Approved
10/24/2003 PLUMBING - FINAL ROHAVER Approved IVRS - Inspection 0000*
10/24/2003 PLUMBING - GAS PRESSURE TEST ROHAVER Approved IVRS - Inspection 0000*
10/24/2003 ELECTRIC - FINAL ROHAVER Approved IVRS - Inspection 0000*
10/24/2003 BUILDING - FINAL ROHAVER Approved IVRS - Inspection 0000*
11/18/2003 FRAMING ROHAVER Approved IVRS - Inspection 0999*/ 1) PLATE BOLT WITHIN 12" EACH END BOTTOM PLATES REQUIRED 2) BOLTS MAXIMUM 48" SPACING ALL BOTTOM PLATES 3) INSTALL 3/4" T-111 SIDING 4) PLAN CALLS FOR 2" X 8" HEADER LAGGED INTO EXISTING WALL FOR LEDGER 5) INSTALL H2.5'S BOTTOM PLATE TO STUD AND STUD TO TOP PLATE 6) INSTALL POSTIVE CONNECTION TRIPLE TOP PLATE TO HOLD IT ALL TOGETHER 7) INSTALL MINIMUM 3 LAG BOLTS NEW STUD INTO EXISTING MASONRY 8) WINDOWS NOT TO PLAN 9) RAFTERS EXCESSIVELY NOTCHED FOR GAS PIPE 10) SKYLIGHT NOT FRAMED IN 11) CANNOT LOCATE RAFTER SPACING ON PLAN 12) MUST NAIL PLYWOOD TO RAFTERS (DO NOT RAILROAD JOINTS-MUST STAGGER 13) UNABEL TO LOCATE GAS RELOCATE ON PLANS 14) STOPPED INSPECTION 15) COMPLETE ALL AND RECALL WHEN READY
01/09/2004 ELECTRIC - INTERMEDIATE HPEDROZA Approved IVRS - Inspection 0000*
01/09/2004 ROOF NAILING HPEDROZA Approved IVRS - Inspection 0000*
01/09/2004 EXT METAL CLIPS/EXT SHEATHING HPEDROZA Approved IVRS - Inspection 0000*