Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03CM01314

Parcel: 129024000


Addresses:

2917 E MALVERN ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/09/2004 FRAMING Approved IVRS - Inspection 0000*
11/18/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) PLATE BOLT WITHIN 12" EACH END BOTTOM PLATES REQUIRED 2) BOLTS MAXIMUM 48" SPACING ALL BOTTOM PLATES 3) INSTALL 3/4" T-111 SIDING 4) PLAN CALLS FOR 2" X 8" HEADER LAGGED INTO EXISTING WALL FOR LEDGER 5) INSTALL H2.5'S BOTTOM PLATE TO STUD AND STUD TO TOP PLATE 6) INSTALL POSTIVE CONNECTION TRIPLE TOP PLATE TO HOLD IT ALL TOGETHER 7) INSTALL MINIMUM 3 LAG BOLTS NEW STUD INTO EXISTING MASONRY 8) WINDOWS NOT TO PLAN 9) RAFTERS EXCESSIVELY NOTCHED FOR GAS PIPE 10) SKYLIGHT NOT FRAMED IN 11) CANNOT LOCATE RAFTER SPACING ON PLAN 12) MUST NAIL PLYWOOD TO RAFTERS (DO NOT RAILROAD JOINTS-MUST STAGGER 13) UNABEL TO LOCATE GAS RELOCATE ON PLANS 14) STOPPED INSPECTION 15) COMPLETE ALL AND RECALL WHEN READY