Permit: T03CM01241
Permit Details
Apply Date:
03/11/2003
Applicant:
MONTEREY HOMES CONSTRUCTION INC *C
Description:
SFR:TD#15-21-90
Contractors:
- MONTEREY HOMES CONSTRUCTION INC *C
Permit Reviews
Permit Number - T03CM01241
Permit Status: Final
Permit Description: SFR:TD#15-21-90
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
03/11/2003 | RESIDENTIAL BLDG/ZONING/FLOOD-WALK THRU | 03/14/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM01241
Permit Status: Final
Permit Description: SFR:TD#15-21-90
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
03/11/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T03CM01241
Permit Description: SFR:TD#15-21-90
Total Completed Inspections - 23
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/25/2003 | ELECTRIC - UFER | RFREIDIN | Approved | IVRS - Inspection 0000* |
04/25/2003 | BUILDING PRE-SLAB | RFREIDIN | Approved | IVRS - Inspection 0000* |
04/25/2003 | EXCAVATION/LAYOUT REBAR & ZON | RFREIDIN | Approved | IVRS - Inspection 0000* |
05/09/2003 | ELECTRIC - TEMPORARY SERVICE | RFREIDIN | Approved | IVRS - Inspection 0000* |
05/09/2003 | ELECTRIC - CABLE DROP | RFREIDIN | Approved | IVRS - Inspection 0000* |
05/22/2003 | ROOF NAILING | RFREIDIN | Approved | IVRS - Inspection 0000* |
06/03/2003 | EXT METAL CLIPS/EXT SHEATHING | RFREIDIN | Approved | IVRS - Inspection 0000*/ 1) FLAT VENT FOR TOILET, ROLL UP AS HIGH AS POSSIBLE MINIMUM UPPER 3RD' 2) PLUG HOLES IN CLEAN OUT FITTING 3) MOVE WATER HEATER FLUE 1" CLEAR 4) FIREBLOCK STAIR 5) PLUG HOLE IN FIRESTOP LID NEXT TO STAIR, FIREBLOCK STAIR STINGERS 6) STRAP D/DUCT 7) PEX AT KITCHEN RADIUS BEND TO SHARP 8) 2ND FLOOR NEED COMB/RELIEF AIR FRONT BATH 9) DIVERTER STUDS BOTH NOTCHED 10) FHA OVER 2ND FLOR WATER HEATER TOP PLATE, INSULATE BEHIND TUBS 11) ANCHOR BOLTS NOTE "C" GARAGE WEST 1/2 DIAMETER AT 16" ON CENTER 12) T & P TO BE AN APPROVED PIPE |
06/05/2003 | PLUMBING - GAS PRESSURE TEST | RFREIDIN | Approved | IVRS - Inspection 0000* |
06/05/2003 | PLUMBING - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection 0000* |
06/05/2003 | ELECTRIC - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection 0000* |
06/05/2003 | FRAMING | RFREIDIN | Approved | IVRS - Inspection 0000* |
06/06/2003 | STUCCO MESH | RFREIDIN | Approved | IVRS - Inspection 0000* |
06/09/2003 | MECHANICAL - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection 0000* |
06/12/2003 | SHEET ROCK NAILING | RFREIDIN | Approved | IVRS - Inspection 0000* |
07/29/2003 | PERMIT FINALED | RFREIDIN | Approved | |
07/29/2003 | MECHANICAL - FINAL | RFREIDIN | Approved | IVRS - Inspection 0000* |
07/29/2003 | PLUMBING - FINAL | RFREIDIN | Approved | IVRS - Inspection 0000* |
07/29/2003 | PLUMBING - SEWER HCS CONNECT | RFREIDIN | Approved | |
07/29/2003 | PLUMBING - YARD WTR LINE/TEST | RFREIDIN | Approved | |
07/29/2003 | PLUMBING - ROUGH, SOIL | RFREIDIN | Approved | |
07/29/2003 | ELECTRIC - FINAL | RFREIDIN | Approved | IVRS - Inspection 0000* SENT TO TEP ON 7/30AM |
07/29/2003 | BUILDING - FINAL | RFREIDIN | Approved | IVRS - Inspection 0000* |
07/29/2003 | U VALUE FOR WINDOW | RFREIDIN | Approved |