Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T03CM01241
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/03/2003 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000*/ 1) FLAT VENT FOR TOILET, ROLL UP AS HIGH AS POSSIBLE MINIMUM UPPER 3RD' 2) PLUG HOLES IN CLEAN OUT FITTING 3) MOVE WATER HEATER FLUE 1" CLEAR 4) FIREBLOCK STAIR 5) PLUG HOLE IN FIRESTOP LID NEXT TO STAIR, FIREBLOCK STAIR STINGERS 6) STRAP D/DUCT 7) PEX AT KITCHEN RADIUS BEND TO SHARP 8) 2ND FLOOR NEED COMB/RELIEF AIR FRONT BATH 9) DIVERTER STUDS BOTH NOTCHED 10) FHA OVER 2ND FLOR WATER HEATER TOP PLATE, INSULATE BEHIND TUBS 11) ANCHOR BOLTS NOTE "C" GARAGE WEST 1/2 DIAMETER AT 16" ON CENTER 12) T & P TO BE AN APPROVED PIPE | |
05/27/2003 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection 0000*/ 1) NO AD4 PAGE IN PLAN SET, NEED DETAIL ON GRADUATED GABLE TRUSS OVER FRAMING 2) NEED TRUSS DRAWINGS | |
05/22/2003 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection 0000*/ 1) AHUS26 REQUIRES 16D'S 7206 POUNDS MAX 2) FIND OUT IF GRADUATED TRUSS REQUIRED SPECIFIC FASTENERS 14/A/SD4 NOT ON PLAN 4) VERTICAL PT LOADING VERTICAL FROM TRUSS TO FLOOR 4 2 X 4'S WITH 2 X 8 BLOCK IN BETWEEN FLOORS 5) NEED TRUSS DRAWINGS OK TO DRY IN DON'T LOAD |