Permit: T03CM01241

Parcel: 141305140

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T03CM01241

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
06/03/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*/ 1) FLAT VENT FOR TOILET, ROLL UP AS HIGH AS POSSIBLE MINIMUM UPPER 3RD' 2) PLUG HOLES IN CLEAN OUT FITTING 3) MOVE WATER HEATER FLUE 1" CLEAR 4) FIREBLOCK STAIR 5) PLUG HOLE IN FIRESTOP LID NEXT TO STAIR, FIREBLOCK STAIR STINGERS 6) STRAP D/DUCT 7) PEX AT KITCHEN RADIUS BEND TO SHARP 8) 2ND FLOOR NEED COMB/RELIEF AIR FRONT BATH 9) DIVERTER STUDS BOTH NOTCHED 10) FHA OVER 2ND FLOR WATER HEATER TOP PLATE, INSULATE BEHIND TUBS 11) ANCHOR BOLTS NOTE "C" GARAGE WEST 1/2 DIAMETER AT 16" ON CENTER 12) T & P TO BE AN APPROVED PIPE
05/27/2003 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) NO AD4 PAGE IN PLAN SET, NEED DETAIL ON GRADUATED GABLE TRUSS OVER FRAMING 2) NEED TRUSS DRAWINGS
05/22/2003 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) AHUS26 REQUIRES 16D'S 7206 POUNDS MAX 2) FIND OUT IF GRADUATED TRUSS REQUIRED SPECIFIC FASTENERS 14/A/SD4 NOT ON PLAN 4) VERTICAL PT LOADING VERTICAL FROM TRUSS TO FLOOR 4 2 X 4'S WITH 2 X 8 BLOCK IN BETWEEN FLOORS 5) NEED TRUSS DRAWINGS OK TO DRY IN DON'T LOAD