Permit: T03CM00307
Permit Details
Status:
C of o
Type:
SINGLE FAMILY NEW
Address:
2499 S TIMBERLINE AV
Address NEW:
2499 S TIMBERLINE AV
Apply Date:
01/23/2003
Applicant:
N/A
Description:
TOWNHOMES:TD#15-57-88
Contractors:
- KOCJAN BUILDERS L L C
Outstanding Activity Conditions
Permit Number - T03CM00307
Permit Status: C of o
Permit Description: TOWNHOMES:TD#15-57-88
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 01/23/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T03CM00307
Permit Description: TOWNHOMES:TD#15-57-88
Total Completed Inspections - 24
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/27/2003 | PLUMBING - SEWER HCS CONNECT | HLEYVA | Approved | IVRS - Inspection 0000* |
| 01/27/2003 | PLUMBING - ROUGH, SOIL | HLEYVA | Approved | IVRS - Inspection 0000* |
| 01/28/2003 | ELECTRIC - UFER | DSANTACR | Approved | IVRS - Inspection 0000*NOTES PLANS CALL OUT 1/0 UFER, CONTR. INSTALLED #4 CODE BUT NOT PER PLAN. 150 AMP SERVICE. |
| 01/29/2003 | BUILDING PRE-SLAB | LHANLY | Approved | IVRS - Inspection 0000* |
| 01/29/2003 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | IVRS - Inspection 0000* |
| 05/30/2003 | ELECTRIC - TEMPORARY SERVICE | JORTA | Approved | IVRS - Inspection 0000* |
| 05/30/2003 | ELECTRIC - CABLE DROP | JORTA | Approved | IVRS - Inspection 0000* |
| 01/16/2004 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection 0000*/ 1) 10 PSI PRESSURE TEST APPROVED FROM METER TO ROOF TOP UNIT AND DRYER LOCATION |
| 01/16/2004 | U VALUE FOR WINDOW | LHANLY | Approved | IVRS - Inspection 0000* |
| 01/16/2004 | FRAMING | LHANLY | Approved | IVRS - Inspection 0000* |
| 01/16/2004 | ROOF NAILING | LHANLY | Approved | IVRS - Inspection 0000* |
| 01/16/2004 | EXT METAL CLIPS/EXT SHEATHING | LHANLY | Approved | IVRS - Inspection 0000* |
| 01/20/2004 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection 0000*/ 1) OK ROUGH ELECTRIC |
| 01/21/2004 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection 0000*/ CORRECTIONS HAVE BEEN MADE. OK FOR SHEET ROCK. |
| 01/22/2004 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection 0000*/ WTR TEST WASTE AND VENT THRU ROOF APPROVED. H20 60 PSI TEST APPROVED. WILL NEED TO SEE CLOSET FLANGES PRIOR TO SETTING STOOLS. |
| 02/09/2004 | SHEET ROCK NAILING | HLEYVA | Approved | IVRS - Inspection 0000* |
| 02/17/2004 | STUCCO MESH | HLEYVA | Approved | IVRS - Inspection 0000* |
| 07/07/2004 | TEP CLEARANCE - PM | JKOZUCH | Approved | PER STEVE LONG |
| 09/16/2004 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :*/OK FOR FINAL |
| 09/16/2004 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* |
| 09/16/2004 | PLUMBING - YARD WTR LINE/TEST | RRICH | Approved | IVRS - Inspection :* |
| 09/20/2004 | ELECTRIC - FINAL | JORTA | Approved | |
| 09/21/2004 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection :*APPROVED. |
| 09/22/2004 | PERMIT FINALED | JWEATHER | Approved |