Permit: T03CM00191
Permit Details
Status:
Expired
Type:
SINGLE FAMILY ALTERATION
Address:
2546 N FONTANA AV
Address NEW:
2546 N FONTANA AV
Apply Date:
01/16/2003
Applicant:
TONY MELTON
Description:
ENCLOSE:PATIO TO BEDROOM/BATHROOM
Permit Reviews
Permit Number - T03CM00191
Permit Status: Expired
Permit Description: ENCLOSE:PATIO TO BEDROOM/BATHROOM
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/16/2003 | RESIDENTIAL BLDG/ZONING/FLOOD/WWM | 04/01/2003 | COMPLETED |
| 04/01/2003 | OTHER | 05/14/2003 | COMPLETED |
| 07/09/2003 | RESUBMITTAL | 07/25/2003 | COMPLETED |
| 07/28/2003 | RESUBMITTAL | 08/04/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM00191
Permit Status: Expired
Permit Description: ENCLOSE:PATIO TO BEDROOM/BATHROOM
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 01/16/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T03CM00191
Permite Description: ENCLOSE:PATIO TO BEDROOM/BATHROOM
Total Outstanding Inspections - 10
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| EXT METAL CLIPS/EXT SHEATHING | N/A | Not Inspected | ||
| ROOF NAILING | N/A | Not Inspected | ||
| STUCCO MESH | N/A | Not Inspected | ||
| U VALUE FOR WINDOW | N/A | Not Inspected | ||
| SHEET ROCK NAILING | N/A | Not Inspected | ||
| BUILDING - FINAL | N/A | Not Inspected | ||
| ELECTRIC - FINAL | N/A | Not Inspected | ||
| PLUMBING - GAS PRESS TEST FNL | N/A | Not Inspected | ||
| PLUMBING - FINAL | N/A | Not Inspected | ||
| MECHANICAL - FINAL | N/A | Not Inspected |
Completed Inspections
Permit Status: Expired
Permit Number: T03CM00191
Permit Description: ENCLOSE:PATIO TO BEDROOM/BATHROOM
Total Completed Inspections - 9
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/12/2003 | PLUMBING - ROUGH, SOIL | HPEDROZA | Approved | IVRS - Inspection 0000* |
| 08/12/2003 | FRAMING | HPEDROZA | Approved | |
| 08/12/2003 | STEM WALL/RETAINING WALL | HPEDROZA | Approved | IVRS - Inspection 0000* |
| 08/12/2003 | EXCAVATION/LAYOUT REBAR & ZON | HPEDROZA | Approved | IVRS - Inspection 0000* |
| 08/15/2003 | BUILDING PRE-SLAB | BSTEVENS | Approved | IVRS - Inspection 0000* |
| 11/26/2003 | MECHANICAL - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection 0999* |
| 11/26/2003 | PLUMBING - GAS PRESSURE TEST | JRIVA | Approved | IVRS - Inspection 0999* |
| 11/26/2003 | PLUMBING - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection 0999*/ 1) MAKE UP ALL GROUNDS IN ELECTRIC BOXES AND SECURE WITH MECHANICAL FASTENERS 2) NAIL PROTECT ALL PLUMBING WITHIN 1 1/4" OF STUD WALL SURFACES INCLUDING GAS LINES 3) KITCHEN SINK VENT NOT COMPLETE 4) GROUND UNIONS NOT ALLOWED INCLOSED IN WALL FOR GAS LINE USE A LEFT AND RIGHT HANDED NIPPLE AND COUPLING 5) HARD WIRED SMOKE DETECTORS REQUIRED IN BEDROOM AND ROOM LEADING TO BEDROOM 6) INSTALL 1 1/2" (R.6) INSUALTION AND VAPOR BARRIER ON DUCT WORK 7) GALVANIZED PIPE AND VALVE NOT ALLOWED IN SLAB/WALL 8) CLOSET LIGHT MUST BE AT LEAST 12" IN FRONT OF SHELF 9) ALL WIRES MUST TERMINATE IN APPROVED BOXES |
| 11/26/2003 | ELECTRIC - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection 0999* |