Permit Details

Status:
Expired
Type:
SINGLE FAMILY ALTERATION
Address NEW:
2546 N FONTANA AV
Apply Date:
01/16/2003
Applicant:
TONY MELTON
Description:
ENCLOSE:PATIO TO BEDROOM/BATHROOM

Permit Reviews

Permit Number - T03CM00191
Permit Status: Expired
Permit Description: ENCLOSE:PATIO TO BEDROOM/BATHROOM
Start Date Submittal Complete Date Status  
01/16/2003 RESIDENTIAL BLDG/ZONING/FLOOD/WWM 04/01/2003 COMPLETED Review Details
04/01/2003 OTHER 05/14/2003 COMPLETED Review Details
07/09/2003 RESUBMITTAL 07/25/2003 COMPLETED Review Details
07/28/2003 RESUBMITTAL 08/04/2003 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T03CM00191
Permit Status: Expired
Permit Description: ENCLOSE:PATIO TO BEDROOM/BATHROOM
Total Outstanding Activity Conditions - 1
Date Name
01/16/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T03CM00191
Permite Description: ENCLOSE:PATIO TO BEDROOM/BATHROOM
Total Outstanding Inspections - 10
Last Inspection Date Description Inspector Results Comments
EXT METAL CLIPS/EXT SHEATHING N/A Not Inspected
ROOF NAILING N/A Not Inspected
STUCCO MESH N/A Not Inspected
U VALUE FOR WINDOW N/A Not Inspected
SHEET ROCK NAILING N/A Not Inspected
BUILDING - FINAL N/A Not Inspected
ELECTRIC - FINAL N/A Not Inspected
PLUMBING - GAS PRESS TEST FNL N/A Not Inspected
PLUMBING - FINAL N/A Not Inspected
MECHANICAL - FINAL N/A Not Inspected

Completed Inspections

Permit Status: Expired
Permit Number: T03CM00191
Permit Description: ENCLOSE:PATIO TO BEDROOM/BATHROOM
Total Completed Inspections - 9
Date Description Inspector Results Comments
08/12/2003 PLUMBING - ROUGH, SOIL HPEDROZA Approved IVRS - Inspection 0000*
08/12/2003 FRAMING HPEDROZA Approved
08/12/2003 STEM WALL/RETAINING WALL HPEDROZA Approved IVRS - Inspection 0000*
08/12/2003 EXCAVATION/LAYOUT REBAR & ZON HPEDROZA Approved IVRS - Inspection 0000*
08/15/2003 BUILDING PRE-SLAB BSTEVENS Approved IVRS - Inspection 0000*
11/26/2003 MECHANICAL - INTERMEDIATE JRIVA Approved IVRS - Inspection 0999*
11/26/2003 PLUMBING - GAS PRESSURE TEST JRIVA Approved IVRS - Inspection 0999*
11/26/2003 PLUMBING - INTERMEDIATE JRIVA Approved IVRS - Inspection 0999*/ 1) MAKE UP ALL GROUNDS IN ELECTRIC BOXES AND SECURE WITH MECHANICAL FASTENERS 2) NAIL PROTECT ALL PLUMBING WITHIN 1 1/4" OF STUD WALL SURFACES INCLUDING GAS LINES 3) KITCHEN SINK VENT NOT COMPLETE 4) GROUND UNIONS NOT ALLOWED INCLOSED IN WALL FOR GAS LINE USE A LEFT AND RIGHT HANDED NIPPLE AND COUPLING 5) HARD WIRED SMOKE DETECTORS REQUIRED IN BEDROOM AND ROOM LEADING TO BEDROOM 6) INSTALL 1 1/2" (R.6) INSUALTION AND VAPOR BARRIER ON DUCT WORK 7) GALVANIZED PIPE AND VALVE NOT ALLOWED IN SLAB/WALL 8) CLOSET LIGHT MUST BE AT LEAST 12" IN FRONT OF SHELF 9) ALL WIRES MUST TERMINATE IN APPROVED BOXES
11/26/2003 ELECTRIC - INTERMEDIATE JRIVA Approved IVRS - Inspection 0999*