Permit: T03BU01613
Permit Details
Apply Date:
06/17/2003
Applicant:
REV. DAIVD POEDEL
Description:
ADDITION:PORCH AT REAR OF HOUSE T03VL00381
Permit Reviews
Permit Number - T03BU01613
Permit Status: Expired
Permit Description: ADDITION:PORCH AT REAR OF HOUSE T03VL00381
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
06/17/2003 | RESIDENTIAL BLDG/ZONING | 06/18/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03BU01613
Permit Status: Expired
Permit Description: ADDITION:PORCH AT REAR OF HOUSE T03VL00381
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
06/17/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T03BU01613
Permite Description: ADDITION:PORCH AT REAR OF HOUSE T03VL00381
Total Outstanding Inspections - 2
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/07/2003 | EXCAVATION/LAYOUT REBAR & ZON | N/A | Denied | IVRS - Inspection 0999* EXPOSE 1 SIDE OF FOOTINGS |
10/10/2003 | BUILDING - FINAL | N/A | Denied | IVRS - Inspection 0999* 1) LAG BOLTS THROUGH CENTER OF 2 X 6 LEDGER ARE SPACED AT RANDOM INTERVALS OF 1'9" TO 3'8". 2) 2 X 6 RAFTERS SPAN 10'6" @ 24" O.C. 3) LEDGER HAS BEEN ATTACHED TO FACE AT STUCCO/FOAM (2" THICK TOTAL) THEREFORE 16d SINKERS AT ENDS OF LEDGERS DO NOT PENETRATE FRAME. 4) POST CAPS (SIMPSON AC4R)ARE ON ONE SIDE OF POST ONLY WITH 4 NAILS INTO POST AND 6 NAILS INTO BEAM. 5) IT IS UNKNOWN IF THER ARE FOOTINGS UNDER POSTS. |