Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY ADDITION
Address NEW:
5691 S ABBOTTSFORD DR
Apply Date:
05/19/2003
Applicant:
JOE ALLEN FRIEND
Description:
ADDITION:PORCH

Permit Reviews

Permit Number - T03BU01241
Permit Status: Final
Permit Description: ADDITION:PORCH
Start Date Submittal Complete Date Status  
05/19/2003 RESIDENTIAL BLDG/ZONING 05/19/2003 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T03BU01241
Permit Status: Final
Permit Description: ADDITION:PORCH
Total Outstanding Activity Conditions - 1
Date Name
05/19/2003 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T03BU01241
Permit Description: ADDITION:PORCH
Total Completed Inspections - 6
Date Description Inspector Results Comments
05/21/2003 BUILDING PRE-SLAB AMATHIES Approved IVRS - Inspection 0000*NAIL NOT ALLOWED THRU ELECTRIC BOXES TO SUPPORT BOXES. REMOVE NAILS AND SUPPORT WITH SCREWS ON ONE SIDE OR CHANGE BOXES TO REPAIR BOXES.
2.) METAL ELECTRIC BOXES REQUIRE PLASTIC BUSHING IN ALL KNOCK OUTS.
3.) ALL METAL ELECTRIC BOXES MUST BE GROUNDED.
4.) UNTREATED WOOD CANNOT BE IN CONTACT WITH CONCRETE OR LOCATION WITHIN 6" OF SOIL.
5.) OPEN A SECTION OF NORTH AND EAST WALL ALLPY BOTTOM FOR A LENGTH OF 24" AND 12" HIGH.
6.) WINDOW IS TOO SMALL FOR EMERGENCY EXIT. OPENING MUST BE A MINMUM OF 20" WIDE AND 24" HIGH WITH MINIMUM SIZE OF OPENING 5.7 SQ FT MAXIMUM SILL HEIGHT 44"
7.) NOW OPENING BARS ARE NOT ALLOWED ON BED ROOM WINDOWS.
8.) HARD WIRED SMOKE DETECTOR REQUIRED IN NEW BEDROOM.
05/21/2003 EXCAVATION/LAYOUT REBAR & ZON AMATHIES Approved IVRS - Inspection 0000*
06/17/2003 PERMIT FINALED AMATHIES Approved
06/17/2003 BUILDING - FINAL AMATHIES Approved IVRS - Inspection 0000*
06/17/2003 FRAMING AMATHIES Approved IVRS - Inspection 0000*
06/17/2003 ROOF NAILING AMATHIES Approved IVRS - Inspection 0000*

Documents

File Name Document Type  
None CONSTRPLANS VIEW
None DOCUMENTS VIEW