Permit Details

Status:
Final
Type:
SINGLE FAMILY OTHER
Address NEW:
6222 S FONTANA AV
Apply Date:
12/20/2002
Applicant:
NICOLAS RAMOS
Description:
GAS:RECONNECT

Permit Reviews

Permit Number - T02PL02369
Permit Status: Final
Permit Description: GAS:RECONNECT
Start Date Submittal Complete Date Status  
04/14/2003 PLUMBING 04/14/2003 COMPLETED Review Details
06/13/2003 PLUMBING 06/13/2003 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T02PL02369
Permit Status: Final
Permit Description: GAS:RECONNECT
Total Outstanding Activity Conditions - 1
Date Name
12/20/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T02PL02369
Permit Description: GAS:RECONNECT
Total Completed Inspections - 5
Date Description Inspector Results Comments
12/25/2002 PLUMBING - FINAL RMYERS Approved IVRS - Inspection 0999*
1.) ARIZONA LAW REQUIRES THAT ALL GAS REPIPES BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR.
I NEED TO SEE A PRESSURE TEST ON THE ENTIRE SYSTEM. I NEED AN APPROVED ISOMETRIC GAS DRAWING, SHOWING DEVEOPED LENGTH AND BTU CONSUMPTION. ALL PIPING TO BE IN ACCORDANCE WITH STATE PLUMBING CODE.
2.) THERE IS EVIDENCE THAT EXTENSIVE WATER AND DWV REPIPING HAS OCCURED. YOU REQUIRE PERMITS FOR THIS WORK. ASK YOUR PLUMBER ABOUT CODE VIOLATIONS I.E. UNAPPROVED MAT'L IN UNAPPROVED LOCATIONS. UNAPPROVED MAT'L TYPES ETC.
3.) GAS WATER HEATER HAS SEVERAL SERIOUS CODE VIOLATIONS ASK YOUR PLUMBER TO REVIEW CHAPTER 5, AND INSTALL ACCORDINGLY.
12/25/2002 PLUMBING - GAS PRESSURE TEST RMYERS Approved IVRS - Inspection 0999*
07/18/2003 PLUMBING - INTERMEDIATE TRINIVJR Approved IVRS - Inspection 0000*
07/23/2003 PERMIT FINALED TRINIVJR Approved
07/23/2003 PLUMBING - GAS PRESS TEST FNL TRINIVJR Approved IVRS - Inspection 0000* 1) GAS PRESSURE TEST IS OK. 2) GAS SHUT OFF VALVES OK. 3) WATER HEATER FLU VENT IS OK, P&T VALVE & DRAIN IS OK. 4)WALL FURNACE IS EXSISTING IN BEDROOM