Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/23/2003 | PLUMBING - FINAL | Approved | ||
| 07/18/2003 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection 0000* | |
| 06/02/2003 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection 0000*/ 1) GAS PRESSURE TEST FOR 1 1/2" UG GAS LINE FROM METER TO BLDG. SERVICE IS OK 2) OK TO BACKFILL TRENCH UP TO TWO WAY C.O. 3) WATER HEATERS REQUIRE ENCLOSURES, MUST EXTEND P&T DRAINS AND TERMINATE 6" ABOVE PAD 5) MUST PROVIDE AGA OC CSA GAS SHUT OFF VALVES AT ALL APPLIANCES 6) MUST SCREW DOWN WATER HEATER FLU VENTS WITH (3) SHEET METAL SCREWS PER JOINT 7) MUST CONNECT ALL GAS LINES AND PROVIDE AIR TEST ON ENTIRE SYSTEM 8) REMOVE ALL UNIONS IN LINE | |
| 05/30/2003 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection 0000* | |
| 12/25/2002 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999* 1.) ARIZONA LAW REQUIRES THAT ALL GAS REPIPES BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR. I NEED TO SEE A PRESSURE TEST ON THE ENTIRE SYSTEM. I NEED AN APPROVED ISOMETRIC GAS DRAWING, SHOWING DEVEOPED LENGTH AND BTU CONSUMPTION. ALL PIPING TO BE IN ACCORDANCE WITH STATE PLUMBING CODE. 2.) THERE IS EVIDENCE THAT EXTENSIVE WATER AND DWV REPIPING HAS OCCURED. YOU REQUIRE PERMITS FOR THIS WORK. ASK YOUR PLUMBER ABOUT CODE VIOLATIONS I.E. UNAPPROVED MAT'L IN UNAPPROVED LOCATIONS. UNAPPROVED MAT'L TYPES ETC. 3.) GAS WATER HEATER HAS SEVERAL SERIOUS CODE VIOLATIONS ASK YOUR PLUMBER TO REVIEW CHAPTER 5, AND INSTALL ACCORDINGLY. |