Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
824 W 19TH ST
Address NEW:
824 W 19TH ST
Apply Date:
07/01/2002
Applicant:
DORA LOPEZ
Description:
REPAIR:GASLINE

Permit Reviews

Permit Number - T02PL01219
Permit Status: Expired
Permit Description: REPAIR:GASLINE
Start Date Submittal Complete Date Status  
07/01/2002 PLUMBING 07/01/2002 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T02PL01219
Permit Status: Expired
Permit Description: REPAIR:GASLINE
Total Outstanding Activity Conditions - 1
Date Name
07/01/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T02PL01219
Permite Description: REPAIR:GASLINE
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
07/02/2002 PLUMBING - INTERMEDIATE N/A Denied IVRS - Inspection 0999*
07/02/2002 PLUMBING - GAS PRESSURE TEST N/A Denied IVRS - Inspection 0999*
07/02/2002 PLUMBING - FINAL N/A Denied IVRS - Inspection 0999*1.) NEW PIPING UNDERGROUND COVERED BEFORE INSPECTION. 2.) WHERE PIPING MEETS, A RIGHT LEFT NIPPLE AND COUPLING SHALL BE USED (NO UNIONS). 3.) ENTIRE SYSTEM MUST HOLD 10#PRESSURE TEST. 1.) EXPOSE ALL NEW PIPING 2.) REMOVE UNION OR INSTALL AGA BLDG SHUT OFF VALVE. 3.) AIR TEST TO 10#. 4.) DO NOT TEST THROUGH APPLIANCES.

Documents

File Name Document Type  