Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
COMMERCIAL OTHER
Address NEW:
3315 E SPEEDWAY BL
Apply Date:
06/04/2002
Applicant:
CENTERLINE OFFSET INC
Description:
NEW:SEWER LINE
Contractors:
  • J M W CONSTRUCTION INC ,

Permit Reviews

Permit Number - T02PL01096
Permit Status: Final
Permit Description: NEW:SEWER LINE
Start Date Submittal Complete Date Status  
06/04/2002 PLUMBING 06/21/2002 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T02PL01096
Permit Status: Final
Permit Description: NEW:SEWER LINE
Total Outstanding Activity Conditions - 1
Date Name
06/04/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T02PL01096
Permit Description: NEW:SEWER LINE
Total Completed Inspections - 5
Date Description Inspector Results Comments
06/26/2002 PERMIT FINALED RMYERS Approved
06/26/2002 PLUMBING - FINAL RMYERS Approved IVRS - Inspection 0000*1.) INSPECTED 10:30 AM REQUIRES CORRECTIONS 2.) PLEASE POST YOUR ADDRESS. 3.) CORRECTION MADE OK ON REINSPECTION AT 2:15PM CONNECTION MADE OK WATER TEST OK 4.) OK TO COVER.
06/26/2002 PLUMBING - PROGRESS RMYERS Approved IVRS - Inspection 0000*
06/26/2002 PLUMBING - SEWER HCS CONNECT RMYERS Approved IVRS - Inspection 0000*
06/26/2002 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection 0000*1.) MUST PROVIDE WATER TEST ON WASTE & VENT SYSTEM 10 FT HARD. 2) MUST CONNECT VENT FOR SAND INTERCEPTOR ABOVE CENTER LINE OF 4' OUTLET. 3.) MUST USE APPROVED MATERIAL FOR 2" EXPOSED VENT. 4.) REMOVE 4" P-TRAP AND USE A L- SWEEP FOR FLOOR RECEPTOR. 5.) MAKE P.O.C. TO HCS FURTHER DOWN STREAM TO MAKE A STAIGHT RUN INTO HCS CONNECTION. 6.) ELMINATE TWO WAY CO.

Documents

File Name Document Type  
None DEVPLANS VIEW