Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 06/26/2002 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection 0000*1.) MUST PROVIDE WATER TEST ON WASTE & VENT SYSTEM 10 FT HARD. 2) MUST CONNECT VENT FOR SAND INTERCEPTOR ABOVE CENTER LINE OF 4' OUTLET. 3.) MUST USE APPROVED MATERIAL FOR 2" EXPOSED VENT. 4.) REMOVE 4" P-TRAP AND USE A L- SWEEP FOR FLOOR RECEPTOR. 5.) MAKE P.O.C. TO HCS FURTHER DOWN STREAM TO MAKE A STAIGHT RUN INTO HCS CONNECTION. 6.) ELMINATE TWO WAY CO. |
| 06/25/2002 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999* |