Permit: T02PL00201
Permit Details
Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
5615 E FAIRMOUNT ST
Address NEW:
5615 E FAIRMOUNT ST
Apply Date:
01/23/2002
Applicant:
YOUNG PLUMBING AND HEATING
Description:
GASLINE:REPLACE(APA)
Contractors:
- YOUNG PLUMBING AND HEATING
Outstanding Activity Conditions
Permit Number - T02PL00201
Permit Status: Expired
Permit Description: GASLINE:REPLACE(APA)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 01/23/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T02PL00201
Permite Description: GASLINE:REPLACE(APA)
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/25/2002 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection 0999*1.) CAN NOT HAVE A FLEX CONNECTOR EXTEND THROUGH HOUSING OF APPLIANCE SEE SECTION: 1212.0 94 UPC 2.) WATER HTR P&T DRAIN REQUIRES A UNION IN LINE SEE SECTION: 609.4 94 UPC 3.) WATER HTR FLU VENT REQUIRES (3) SCREWS PER JOINT AND VENT CONNECTOR SECTION: 514.2 4.) MUST REMOVE EXSISTING ASBESTOS FLUE VENT & REPLACE WITH DBC WALL B-VENT & CAP. 5.) CONNECT ALL SHUT OFF VALVES IN LINE 6.) RE-TEST SYSTEM 7.) VERY POOL INSTALLATION OF BLOCKS FOR GAS LINE ON ROOF SECTION: 310.1 96 UPC 8.) CAN NOT USE ANY USED PIPE ON A NEW GAS SYSTEM. I MUST VERIFY APPR. STAMPS ON GAS LINE (NO MARKINGS ON PIPE) 9.) MUST PAY REINSPECTION FEE BEFORE NEXT INSPECTIONS. |