Permit: T02EL02481
Permit Details
Apply Date:
12/23/2002
Applicant:
YESENIA GALLARDO
Description:
RECONNECT:ELECTRIC:RETAIL
Outstanding Activity Conditions
Permit Number - T02EL02481
Permit Status: Withdrwn
Permit Description: RECONNECT:ELECTRIC:RETAIL
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/23/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Withdrwn
Permit Number: T02EL02481
Permite Description: RECONNECT:ELECTRIC:RETAIL
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| FIRE - FINAL | N/A | Not Inspected | ||
| 12/27/2002 | ELECTRIC - RECONNECT | N/A | Denied | IVRS - Inspection 0999* |
| 12/27/2002 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection 0999*1.) EXTENDER RINGS ARE NEEDED WHERE MORE THAN 1/4" FROM BOX TO DEVICE OR BRING BOX FLUSH WITH DRYWALL 2.) WE HAVE GROUNDED RECEPTACLES ON AN UNGROUNDED SYSTEM. 3.) PROTECT CABLE FOR WATER HEATER AND FILL UNUSED OPENING. 4.) PLEASE VERIFY PERMIT FOR WATER HEATER NEW. 5.) INSTALL ALL LIGHT FIXTURES THAT ARE MISSING AND COVER PLATES. 6.) OUTSIDE BACK LIGHT BROKEN AND NEEDS TO BE WEATHER PROOF. 7.) SERVICE IS IN DIS REPAIR,WE HAVE MULTIPOLE TERMANATIONS AND UNDER SIZED FOR LOADS. 8.) CANNOT FIND OVER CURRENT DEVICE OR FOR WATER HEATER 9.) A LICENSED L-11 ELECTRICAL CONTRACTOR TO PERFORM WORK. |