Permit Details

Status:
Expired
Type:
COMMERCIAL OTHER
Address NEW:
102 E PALMDALE ST
Apply Date:
11/22/2002
Applicant:
SOUTHWEST ENERGY SOLUTIONS INC , *C
Description:
UPGRADE:ELECTRIC TO 200 AMP (APA)
Contractors:
  • SOUTHWEST ENERGY SOLUTIONS INC , *C

Outstanding Activity Conditions

Permit Number - T02EL02298
Permit Status: Expired
Permit Description: UPGRADE:ELECTRIC TO 200 AMP (APA)
Total Outstanding Activity Conditions - 1
Date Name
11/22/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T02EL02298
Permite Description: UPGRADE:ELECTRIC TO 200 AMP (APA)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
11/25/2002 ELECTRIC - FINAL N/A Denied IVRS - Inspection 0210*GROUND ROD MUST BE A MIN OF 6 FT. APART IDENTIFY ALL CIRCUITS.
A SEALING FITTING IS REQUIRED FOR 1/2" CONDUIT ENTRY TOP SIDE OF PANEL.
NEED TO BOND INTERIOR WATER
GAS BOND ON WRONG PLACE. PLEASE BOND GAS ON SIDE OF METER (CUSTOMER SIDE.)