Permit: T02EL01756
Permit Details
Status:
Closed
Type:
SINGLE FAMILY OTHER
Address:
2628 N FAIR OAKS AV
Address NEW:
2628 N FAIR OAKS AV
Apply Date:
08/27/2002
Applicant:
RINCON MOUNTAIN ELECTRIC ,
Description:
UPGRADE:ELECTRIC 100-200 AMPS
Contractors:
- RINCON MOUNTAIN ELECTRIC ,
Permit Reviews
Permit Number - T02EL01756
Permit Status: Closed
Permit Description: UPGRADE:ELECTRIC 100-200 AMPS
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/27/2002 | ELECTRICAL | 08/27/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02EL01756
Permit Status: Closed
Permit Description: UPGRADE:ELECTRIC 100-200 AMPS
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/27/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Closed
Permit Number: T02EL01756
Permite Description: UPGRADE:ELECTRIC 100-200 AMPS
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/28/2002 | ELECTRIC - SERVICE UPGRADE | N/A | Denied | IVRS - Inspection 0245* |
| 08/28/2002 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection 0245*1.)NOTES INSTALL BUSHED CONNECTOR AT END OF CONDUIT SLEEVES TO PROTECT CABLE FROM ABRASION 300-15C NEC. 2.) SUPPORT RISER USING MIN. 1/4" BOLTS WITHIN 3' OF ENCLOSURE.. |