Permit: T02EL00580
Permit Details
Apply Date:
03/20/2002
Applicant:
MARQUES MARIA CARMEN
Description:
ELECTRIC:UPGRADE 100AMPS
Permit Reviews
Permit Number - T02EL00580
Permit Status: Expired
Permit Description: ELECTRIC:UPGRADE 100AMPS
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/20/2002 | ELECTRICAL | 03/20/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02EL00580
Permit Status: Expired
Permit Description: ELECTRIC:UPGRADE 100AMPS
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 03/20/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T02EL00580
Permite Description: ELECTRIC:UPGRADE 100AMPS
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/14/2002 | ELECTRIC - INTERMEDIATE | N/A | Denied | IVRS - Inspection 0245* |
| 05/14/2002 | ELECTRIC - SERVICE UPGRADE | N/A | Denied | IVRS - Inspection 0245* |
| 05/14/2002 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection 0245*NOTES OWNER OF DWELLING NOT HOME 1.) CHASE NIPPLE NOT AN APPROVED WIRING METHOD FOR CONNECTION OF 1" LB. MUST MUST USE CLOSE NIPPLE LOCKNUT EACH END AND GROUNDING BUSHING BECAUSE OF CONCENTRIC KO. 2.) MUST BOND GAS PIPING. 3.) NEW WIRING INSIDE SUB-PANEL NOT PER CODE, SUB PANEL MUST BE ACCESSABLE ALSO COMPLETE WIRING. |