Permit: T02EL00401
Permit Details
Apply Date:
02/26/2002
Applicant:
HANDY RANDY HOME AND BUSINESS EL
Description:
UPGRADE:ELECTRIC TO 200 AMP
Contractors:
- HANDY RANDY HOME AND BUSINESS EL
Permit Reviews
Permit Number - T02EL00401
Permit Status: Expired
Permit Description: UPGRADE:ELECTRIC TO 200 AMP
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/26/2002 | ELECTRICAL | 02/26/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02EL00401
Permit Status: Expired
Permit Description: UPGRADE:ELECTRIC TO 200 AMP
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 02/26/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T02EL00401
Permite Description: UPGRADE:ELECTRIC TO 200 AMP
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/26/2002 | ELECTRIC - SERVICE UPGRADE | N/A | Denied | IVRS - Inspection 0215* CONDUIT CONNECTIONS AND WIRING, OTHER THAN THE UTILITY COMPANY CONDUCTORS, ARE NOT PERMITTED I THE SECTION RESERVED FOR THE UTILITY COMPANY TEP. SEE TEP SERVICE MANUAL AND NEC ART 230. REMOVAL OF THE METER SHOULD NOT BE REQUIRED TO SERVICE ANY CUSTOMER WIRING. THANKS |
| 03/26/2002 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection 0215* |