Permit: T02CM04976
Permit Details
Apply Date:
10/25/2002
Applicant:
CARRERA CUSTOM HOMES INC ,
Description:
DUPLEX:TD#15-10-66
Contractors:
- CARRERA CUSTOM HOMES INC ,
Outstanding Activity Conditions
Permit Number - T02CM04976
Permit Status: Final
Permit Description: DUPLEX:TD#15-10-66
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/25/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T02CM04976
Permit Description: DUPLEX:TD#15-10-66
Total Completed Inspections - 26
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/19/2002 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | 1.) 4" SDR 35 FROM TIE-IN IN THE STREET TO T-20' INSIDE FENCE OK SADDLE TAP OK TIE-IN OK WATER TEST OK 2.) OK TO BACKFILL. |
| 11/21/2002 | PLUMBING - ROUGH, SOIL | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 12/04/2002 | ELECTRIC - UFER | RHOLLAND | Approved | IVRS - Inspection 0000*OK 1-#4 TO REBAR. |
| 12/04/2002 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection 0000* |
| 12/04/2002 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection 0000* |
| 12/20/2002 | U VALUE FOR WINDOW | HLEYVA | Approved | IVRS - Inspection 0000* |
| 12/20/2002 | ROOF NAILING | HLEYVA | Approved | IVRS - Inspection 0000* |
| 12/20/2002 | EXT METAL CLIPS/EXT SHEATHING | HLEYVA | Approved | IVRS - Inspection 0000* |
| 12/31/2002 | PLUMBING - INTERMEDIATE | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 12/31/2002 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection 0999* 1.) METAL BOXES TO HAVE A CONNECTOR FOR CABLE ALSO EXHAST FANS. 2.) CALES TO HAVE SHEATH AT LEAST 1/4" INTO BOX. 3.) SUPPORT VDV CABLES AT RINGS & DOWN WALLS 4.) METAL BOXES TO BE GROUNDED. 5.) PLEASE PROTECT CABLES PASSING FRAMING MEMBERS AT CORNERS. 6.) WHERE ARE PLANS? |
| 12/31/2002 | FRAMING | HLEYVA | Approved | IVRS - Inspection 0000* |
| 01/01/2003 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 01/03/2003 | STUCCO MESH | AMATHIES | Approved | |
| 01/14/2003 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 01/16/2003 | ELECTRIC - CABLE DROP | MCAPISTR | Approved | IVRS - Inspection 0000*SENT TO TEP 1/17/03 9:15AM PLEASE CALL TEP AND REQUEST A TRENCH INSPECTION. |
| 01/29/2003 | ELECTRIC - TEMPORARY SERVICE | MCAPISTR | Approved | IVRS - Inspection 0000*SENT TO TEP ON 1/30/02 AT 9:15AM.OK TO CLEAR. |
| 03/07/2003 | ELECTRIC - FINAL | MCAPISTR | Approved | IVRS - Inspection 0000*SENT TO TEP ON 3/11/03 AT 9:15AM OK TO CLEAR. |
| 03/10/2003 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000*24,000 BTU PKG. HT PUMPS W/5KW. AUX HT STRIPS. |
| 03/14/2003 | PERMIT FINALED | RMYERS | Approved | |
| 03/14/2003 | ELECTRIC - CONSTRUCTION POWER | MCAPISTR | Approved | |
| 03/14/2003 | ELECTRIC - UNDERGROUND | MCAPISTR | Approved | |
| 03/17/2003 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection 0000* 1.) REMEMBER THAT PLASTIC YARDWATER REQUIRES A MINIMUM OF TWELVE INCHES OF COVER NO CORRECTION NECESSARY. 2.) REQUIRED NOTICE INSIDE ELECTRIC SERVICE PANEL TO STATE NON METALLIC WATER PIPING TO BE CHECKED BY BLDG INSPECTOR. 3.) OK FOR C OF O PENDING ANY OTHER INSPECTIONS. |
| 03/17/2003 | PLUMBING - GAS PRESS TEST FNL | RMYERS | Approved | |
| 03/17/2003 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | |
| 03/17/2003 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection 0000* |
| 03/18/2003 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection 0000* |