Permit: T02CM04875
Permit Details
Status:
Final
Type:
SINGLE FAMILY ADDITION
Address:
7410 E NICARAGUA DR
Address NEW:
7410 E NICARAGUA DR
Apply Date:
10/21/2002
Applicant:
ADAN MATA
Description:
ADDITION:PORCH TO ROOM:STORAGE & WORKSHOP T02VL01927
Permit Reviews
Permit Number - T02CM04875
Permit Status: Final
Permit Description: ADDITION:PORCH TO ROOM:STORAGE & WORKSHOP T02VL01927
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 10/21/2002 | RESIDENTIAL BLDG/ZONING/FLOOD | 10/30/2002 | COMPLETED |
| 12/23/2002 | REVISION | 01/15/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM04875
Permit Status: Final
Permit Description: ADDITION:PORCH TO ROOM:STORAGE & WORKSHOP T02VL01927
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/21/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T02CM04875
Permit Description: ADDITION:PORCH TO ROOM:STORAGE & WORKSHOP T02VL01927
Total Completed Inspections - 13
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/14/2002 | ELECTRIC - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 11/14/2002 | ELECTRIC - UNDERGROUND | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 11/14/2002 | SHEET ROCK NAILING | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 11/14/2002 | ROOF NAILING | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 11/14/2002 | EXT METAL CLIPS/EXT SHEATHING | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 11/14/2002 | BUILDING PRE-SLAB | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 11/14/2002 | EXCAVATION/LAYOUT REBAR & ZON | RFREIDIN | Approved | IVRS - Inspection 0000*/ 1) GALLVANIZED 8D'S AT SIDING 6" AND 12" ON CENTER 3) NEED TO CONFIRM TRUSS CONSTRUCTION WITH PLAN INSPECTOR 4) PRE MADE PANELS ON BEARING WALLS ARE THEY ACCEPTABLE 5) CHECK ALL AMPERAGE ON B/BOARD HTR 240 CIRCUIT AT 20 AMP 1ST ONE WAS 8,000 WATTS=8.3 AMPS 6) ROOF NEED TO LEVEL RIDGE INSTALL GUSSETS AT RIDGE AND WALLS AT COLLAR TIES, MAKE SURE WALLS ARE PLUMBING AND IN LINE 7) SERV PANEL #1 ALSO NEED LOAD CALC 8) FIND GAS LINE SERV NOT TO BE UNDER BLDG 9) NEED HEAT SOURCE FOR NEW ROOMS 10) SUB PANEL IN EAST ADDITION NOT WIRED CORRECTLY 11) MOVE COMBUSTIBLES FROM B/BOARD HTRS, NO HEAT IN REAR BEDROOM 12) REMOVE WINDOW BARS AT BEDROOMS AND DOUBLE CYLINDER DEAD BOLT AT DOORS 13) CHECK LOCATE PROPERTY PINS NEED 6' OR VERIFY MINIMUM SETBACK WITH ZONING 14) #1 AL FEEDER AT SERV.=110 AMPS MAXIMUM 2 SUB PANELS OVER LOAD SERV. |
| 02/12/2003 | FRAMING | AMATHIES | Approved | |
| 05/29/2003 | MECHANICAL - FINAL | DBRITO | Approved | IVRS - Inspection 0000* |
| 05/18/2004 | PERMIT FINALED | DQUINN | Approved | |
| 05/18/2004 | MECHANICAL - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection :* |
| 05/18/2004 | ELECTRIC - FINAL | DQUINN | Approved | IVRS - Inspection :* |
| 05/18/2004 | BUILDING - FINAL | DQUINN | Approved | IVRS - Inspection :* |