Permit Details

Status:
Final
Type:
SINGLE FAMILY ADDITION
Address NEW:
7410 E NICARAGUA DR
Apply Date:
10/21/2002
Applicant:
ADAN MATA
Description:
ADDITION:PORCH TO ROOM:STORAGE & WORKSHOP T02VL01927

Permit Reviews

Permit Number - T02CM04875
Permit Status: Final
Permit Description: ADDITION:PORCH TO ROOM:STORAGE & WORKSHOP T02VL01927
Start Date Submittal Complete Date Status  
10/21/2002 RESIDENTIAL BLDG/ZONING/FLOOD 10/30/2002 COMPLETED Review Details
12/23/2002 REVISION 01/15/2003 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T02CM04875
Permit Status: Final
Permit Description: ADDITION:PORCH TO ROOM:STORAGE & WORKSHOP T02VL01927
Total Outstanding Activity Conditions - 1
Date Name
10/21/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T02CM04875
Permit Description: ADDITION:PORCH TO ROOM:STORAGE & WORKSHOP T02VL01927
Total Completed Inspections - 13
Date Description Inspector Results Comments
11/14/2002 ELECTRIC - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
11/14/2002 ELECTRIC - UNDERGROUND RFREIDIN Approved IVRS - Inspection 0000*
11/14/2002 SHEET ROCK NAILING RFREIDIN Approved IVRS - Inspection 0000*
11/14/2002 ROOF NAILING RFREIDIN Approved IVRS - Inspection 0000*
11/14/2002 EXT METAL CLIPS/EXT SHEATHING RFREIDIN Approved IVRS - Inspection 0000*
11/14/2002 BUILDING PRE-SLAB RFREIDIN Approved IVRS - Inspection 0000*
11/14/2002 EXCAVATION/LAYOUT REBAR & ZON RFREIDIN Approved IVRS - Inspection 0000*/ 1) GALLVANIZED 8D'S AT SIDING 6" AND 12" ON CENTER 3) NEED TO CONFIRM TRUSS CONSTRUCTION WITH PLAN INSPECTOR 4) PRE MADE PANELS ON BEARING WALLS ARE THEY ACCEPTABLE 5) CHECK ALL AMPERAGE ON B/BOARD HTR 240 CIRCUIT AT 20 AMP 1ST ONE WAS 8,000 WATTS=8.3 AMPS 6) ROOF NEED TO LEVEL RIDGE INSTALL GUSSETS AT RIDGE AND WALLS AT COLLAR TIES, MAKE SURE WALLS ARE PLUMBING AND IN LINE 7) SERV PANEL #1 ALSO NEED LOAD CALC 8) FIND GAS LINE SERV NOT TO BE UNDER BLDG 9) NEED HEAT SOURCE FOR NEW ROOMS 10) SUB PANEL IN EAST ADDITION NOT WIRED CORRECTLY 11) MOVE COMBUSTIBLES FROM B/BOARD HTRS, NO HEAT IN REAR BEDROOM 12) REMOVE WINDOW BARS AT BEDROOMS AND DOUBLE CYLINDER DEAD BOLT AT DOORS 13) CHECK LOCATE PROPERTY PINS NEED 6' OR VERIFY MINIMUM SETBACK WITH ZONING 14) #1 AL FEEDER AT SERV.=110 AMPS MAXIMUM 2 SUB PANELS OVER LOAD SERV.
02/12/2003 FRAMING AMATHIES Approved
05/29/2003 MECHANICAL - FINAL DBRITO Approved IVRS - Inspection 0000*
05/18/2004 PERMIT FINALED DQUINN Approved
05/18/2004 MECHANICAL - INTERMEDIATE DQUINN Approved IVRS - Inspection :*
05/18/2004 ELECTRIC - FINAL DQUINN Approved IVRS - Inspection :*
05/18/2004 BUILDING - FINAL DQUINN Approved IVRS - Inspection :*

Documents

File Name Document Type  
T02CM04875 2025 MASS-UPLOAD.PDF DOCUMENTS VIEW