Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY NEW
Apply Date:
10/14/2002
Applicant:
U S HOME OF ARIZONA *P
Description:
SFR:TD#15-37-12
Contractors:
  • U S HOME OF ARIZONA *P

Permit Reviews

Permit Number - T02CM04776
Permit Status: Final
Permit Description: SFR:TD#15-37-12
Start Date Submittal Complete Date Status  
10/14/2002 RESIDENTIAL BLDG/ZONING/FLOOD 10/23/2002 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T02CM04776
Permit Status: Final
Permit Description: SFR:TD#15-37-12
Total Outstanding Activity Conditions - 1
Date Name
10/14/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T02CM04776
Permit Description: SFR:TD#15-37-12
Total Completed Inspections - 27
Date Description Inspector Results Comments
12/04/2002 PLUMBING - SEWER HCS CONNECT RFREIDIN Approved IVRS - Inspection 0000*
12/04/2002 PLUMBING - YARD WTR LINE/TEST RFREIDIN Approved IVRS - Inspection 0000*
12/04/2002 PLUMBING - ROUGH, SOIL RFREIDIN Approved IVRS - Inspection 0000*
12/05/2002 ELECTRIC - UFER RFREIDIN Approved IVRS - Inspection 0000*
12/05/2002 BUILDING PRE-SLAB RFREIDIN Approved IVRS - Inspection 0000*
12/05/2002 EXCAVATION/LAYOUT REBAR & ZON RFREIDIN Approved IVRS - Inspection 0000*
12/24/2002 ROOF NAILING DBRITO Approved IVRS - Inspection 0000*
12/26/2002 EXT METAL CLIPS/EXT SHEATHING RFREIDIN Approved IVRS - Inspection 0000*/ 1) FROM LAST INSPECTION, ALL 3 PT BEARING TRUSSES TO BE SUPPORTED INCLUDING FRONT GABLE 3 PT BEARING TRUSS 2) FROM LAST INSPECTION, DO SHEAR WALLS GO TO ROOF DECK FOR SHEAR TRANSFER, OR IS GABLE END TRUSS A STRUCTURAL STRUT ? 3) TRUSS MISSING GUSSET PLATES BOTH SIDE ABOVE SMALL CLOSET IN LIVING ROOM 4) STUD SPACING TO BE 12" ON CENTER AT GARAGE TO LIVING ROMM WALL WILL CHECK AT INTERMEDIATE INSPECTION
01/09/2003 MECHANICAL - INTERMEDIATE MTESTER Approved IVRS - Inspection 0000*
01/09/2003 PLUMBING - GAS PRESSURE TEST MTESTER Approved IVRS - Inspection 0000*
01/09/2003 PLUMBING - INTERMEDIATE MTESTER Approved IVRS - Inspection 0000*
01/09/2003 ELECTRIC - INTERMEDIATE MTESTER Approved IVRS - Inspection 0000*
01/09/2003 U VALUE FOR WINDOW MTESTER Approved IVRS - Inspection 0000*
01/09/2003 FRAMING MTESTER Approved IVRS - Inspection 0000*
01/13/2003 STUCCO MESH RFREIDIN Approved IVRS - Inspection 0000*
01/22/2003 SHEET ROCK NAILING MTESTER Approved IVRS - Inspection 0000*
02/07/2003 ELECTRIC - TEMPORARY SERVICE HPEDROZA Approved IVRS - Inspection 0000*
02/07/2003 ELECTRIC - CABLE DROP HPEDROZA Approved IVRS - Inspection 0000*
03/10/2003 PERMIT FINALED RFREIDIN Approved
03/10/2003 MECHANICAL - FINAL RFREIDIN Approved IVRS - Inspection 0000*
03/10/2003 MECHANICAL - FINAL DBRITO Approved IVRS - Inspection 0999*
03/10/2003 PLUMBING - FINAL RFREIDIN Approved IVRS - Inspection 0000*
03/10/2003 PLUMBING - FINAL DBRITO Approved IVRS - Inspection 0999*
03/10/2003 ELECTRIC - FINAL RFREIDIN Approved IVRS - Inspection 0000*
03/10/2003 ELECTRIC - FINAL DBRITO Approved IVRS - Inspection 0999*
03/10/2003 BUILDING - FINAL RFREIDIN Approved IVRS - Inspection 0000*
03/10/2003 BUILDING - FINAL DBRITO Approved IVRS - Inspection 0999*/ 1) DRIVE WAY BEING POURED