Permit: T02CM04776

Parcel: 141303730


Addresses:

10382 E OAKBROOK ST


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T02CM04776

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
01/02/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*/ 1) ALL CORRECTIONS REQUESTED FROM LAST INSPECTION ARE COMPLETED
12/26/2002 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) FROM LAST INSPECTION, ALL 3 PT BEARING TRUSSES TO BE SUPPORTED INCLUDING FRONT GABLE 3 PT BEARING TRUSS 2) FROM LAST INSPECTION, DO SHEAR WALLS GO TO ROOF DECK FOR SHEAR TRANSFER, OR IS GABLE END TRUSS A STRUCTURAL STRUT ? 3) TRUSS MISSING GUSSET PLATES BOTH SIDE ABOVE SMALL CLOSET IN LIVING ROOM 4) STUD SPACING TO BE 12" ON CENTER AT GARAGE TO LIVING ROMM WALL WILL CHECK AT INTERMEDIATE INSPECTION
12/24/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) PROVIDE CLIPS AT LEDGER ON WINDOW 2) CLIPS AT JACK TRUSS TO TOP PLATE
12/24/2002 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000* 1) BLOCK UNDER ALL 3PT BEARING TURSSES, INCLUDING GABLE END TRUSSES 2) RUN SHEAR UP TO ROOF DECK, OR PROVIDE INFORMATION FOR DRAG STRUCTURAL TURSSES, B CONNECTION FOR SHEAR TRANSFER.
12/19/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) PROTECT PLUMBING AT OUTSIDE BOTTOM PLATE 2) NO TRUSS CALC'S