Permit: T02CM04683
Permit Details
Apply Date:
10/07/2002
Applicant:
N/A
Description:
SHELL BUILDING
Architects:
- MORROW, KEVIN THOMAS
Contractors:
- COMBS CONSTRUCTION INC , FRED
Permit Reviews
Permit Number - T02CM04683
Permit Status: Final
Permit Description: SHELL BUILDING
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
10/07/2002 | 3RD PARTY REVIEW-COMMERCIAL | 10/31/2002 | COMPLETED |
11/05/2002 | REVISION | 11/07/2002 | COMPLETED |
11/08/2002 | REVISION | 12/06/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM04683
Permit Status: Final
Permit Description: SHELL BUILDING
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
10/07/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T02CM04683
Permit Description: SHELL BUILDING
Total Completed Inspections - 27
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/08/2002 | ELECTRIC - UFER | JORTA | Approved | IVRS - Inspection 0000*3/0 CU. 20FT & FOOTING APPROVED. |
11/13/2002 | BUILDING - FINAL | LHANLY | Approved | 1.) HALL DOOR IS ON ADA ROUTE AND REQUIRES LEVER HARDWARE ( ADAAG 4.13.19) 2.) PROVIDE APPROVED MECHANICAL FINAL. |
11/13/2002 | STEM WALL/RETAINING WALL | LHANLY | Approved | IVRS - Inspection 0000* |
11/13/2002 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | IVRS - Inspection 0000* |
11/19/2002 | PLUMBING - INTERMEDIATE | RMYERS | Approved | ABS DWV UNDERGROUND FOR DENTAL OFFICE OK OK TO BACKFILL. POINT OF CONNECTION TO EXISTING OK. |
11/20/2002 | BUILDING PRE-SLAB | LHANLY | Approved | IVRS - Inspection 0000* |
12/10/2002 | ELECTRIC - SERVICE RELOCATION | RMAJUTA | Approved | IVRS - Inspection 0000* |
12/10/2002 | ELECTRIC - UNDERGROUND | RMAJUTA | Approved | UNDERGROUND 2-4" PVC'S SER TO TRANS APPROVED. |
12/11/2002 | ROOF NAILING | LHANLY | Approved | DETAIL 204 CALL FOR H3 CLIPS TO LEDGER. CLIPS WERE INSTALLED WITH 2 1/2" 8D TO TOP OF DECKING THIS REDUCES LOAD FACTOR IS IT STILL OK? 2.) DETAIL 205 CALLS FOR A34 CLIPS AND H3 CLIPS THESE WERE NOT INSTALLED. 3.) WERE ANY FACE NAILS REQUIRED ON 4X LEDGER? |
12/12/2002 | EXT METAL CLIPS/EXT SHEATHING | LHANLY | Approved | IVRS - Inspection 0000* |
12/12/2002 | REINFORCED MASONRY PRE-GROUT | LHANLY | Approved | IVRS - Inspection 0000* |
12/13/2002 | FRAMING | LHANLY | Approved | IVRS - Inspection 0000*H3 CLIP NAILED THROUGH OSB APPROVED APPROVED TLCP ENGINEERING SEE ATTACHED |
12/17/2002 | STUCCO MESH | LHANLY | Approved | IVRS - Inspection 0000* |
01/06/2003 | BUILDING ABOVE CEILING | AMATHIES | Approved | IVRS - Inspection 0000* |
01/08/2003 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | REPAIR/REPLACE BAD WATER FLOW SWITCH ON RISER. |
01/10/2003 | MECHANICAL - TEMP PWR FOR TEST | CWILLIAM | Approved | |
01/10/2003 | PLUMBING - TEMP POWER FOR TEST | RMYERS | Approved | |
01/10/2003 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection 0000*SENT TO TEP ON 1/10/03 2:15PM. |
01/10/2003 | ELECTRIC - TEMP POWER FOR TEST | DSANTACR | Approved | |
01/10/2003 | ELECTRIC - TEMPORARY POLE | DSANTACR | Approved | |
01/10/2003 | ELECTRIC - TEMPORARY POLE | DSANTACR | Approved | IVRS - Inspection 0000*COURTESY INSP. |
01/10/2003 | BUILDING - TEMP POWER FOR TEST | AMATHIES | Approved | |
01/13/2003 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
01/14/2003 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection 0000*1.) SHELL BLDG ADDITION OK 2.) OK FOR C OF O PENDING ANY OTHER INSPECTION. |
01/15/2003 | PERMIT FINALED | JEGAN | Approved | |
01/15/2003 | FIRE - FINAL | JEGAN | Approved | IVRS - Inspection 0000* |
01/15/2003 | FIRE SPKLR - FINAL | JEGAN | Approved | IVRS - Inspection 0000* |