Permit: T02CM04433
Permit Details
Status:
Expired
Type:
SINGLE FAMILY ADDITION
Address:
7909 E BEVERLY ST
Address NEW:
7909 E BEVERLY ST
Apply Date:
09/20/2002
Applicant:
GLEN PETERSON
Description:
ADDITION:BATHROOM & WALK IN CLOSET
Permit Reviews
Permit Number - T02CM04433
Permit Status: Expired
Permit Description: ADDITION:BATHROOM & WALK IN CLOSET
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/03/2003 | REVISION | 01/03/2003 | COMPLETED |
| 09/20/2002 | RESIDENTIAL BLDG/ZONING/FLOOD/WWM | 10/11/2002 | COMPLETED |
| 12/23/2002 | REVISION | 12/24/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM04433
Permit Status: Expired
Permit Description: ADDITION:BATHROOM & WALK IN CLOSET
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/20/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T02CM04433
Permite Description: ADDITION:BATHROOM & WALK IN CLOSET
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/05/2003 | BUILDING - FINAL | N/A | Denied | IVRS - Inspection 0999*/1) PROVIDE OUTLET COVER @ EXIT. 2) DOUBLE KEY DEAD BOLT NOT ALLOWED AT EXIT. 3) MECH NOT COMPLETE. |
| 09/05/2003 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection 0999* |
| 09/05/2003 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection 0999* |
Completed Inspections
Permit Status: Expired
Permit Number: T02CM04433
Permit Description: ADDITION:BATHROOM & WALK IN CLOSET
Total Completed Inspections - 11
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/04/2002 | PLUMBING - ROUGH, SOIL | RFREIDIN | Approved | IVRS - Inspection 0000*/ 1) PLEASE VERIFY SEWER HCS DEPTH, BEFORE COVERING SOIL LINES WITH CONCRETE, LAYOUT AND WATER TEST OK |
| 11/05/2002 | EXCAVATION/LAYOUT REBAR & ZON | EDURAZO | Approved | IVRS - Inspection 0000* |
| 11/27/2002 | PLUMBING - YARD WTR LINE/TEST | DBRITO | Approved | IVRS - Inspection 0000* |
| 12/27/2002 | MECHANICAL - INTERMEDIATE | DBRITO | Approved | IVRS - Inspection 0999* |
| 12/27/2002 | PLUMBING - INTERMEDIATE | DBRITO | Approved | IVRS - Inspection 0999* |
| 12/27/2002 | ELECTRIC - INTERMEDIATE | DBRITO | Approved | IVRS - Inspection 0999* PLAN DOES NOT REFLECT AS BUILT. WORK SUBSTANDARD. NOT READY FOR INSPECTION. I WOULD LIKE TO MEET WITH CONTRACTOR IF POSSIBLE @ NEXT INSPECTION. |
| 12/27/2002 | FRAMING | DBRITO | Approved | IVRS - Inspection 0999* PLANS DOES NOT REFLECT AS BUILT. WORK SUBSTANDARD. NOT READY FOR INSPECTION. I WOULD LIKE TO MEET WITH CONTRACTOR IF POSSIBLE @ NEXT INSPECTION |
| 12/27/2002 | ROOF NAILING | DBRITO | Approved | IVRS - Inspection 0999* PLAN DOES NOT REFLECT AS BUILDT. WORK SUBSTANDARD. NOT READY FOR INSPECTION. I WOULD LIKE TO MEET WITH CONTRACTOR IF POSSIBLE @ NEXT INSPECTION |
| 02/21/2003 | PLUMBING - SEWER HCS CONNECT | DBRITO | Approved | IVRS - Inspection 0000*/ 1) OK TO BACKFILL |
| 03/10/2003 | SHEET ROCK NAILING | DBRITO | Approved | IVRS - Inspection 0000* |
| 03/10/2003 | EXT METAL CLIPS/EXT SHEATHING | DBRITO | Approved | IVRS - Inspection 0000* |