Permit: T02CM04358
Permit Details
Apply Date:
09/16/2002
Applicant:
SONORA EXPEDITING
Description:
NEW:CREDIT UNION
Architects:
- ACORN, KIM BRIAN
Contractors:
- GILES CONSTRUCTION INC
Permit Reviews
Permit Number - T02CM04358
Permit Status: C of o
Permit Description: NEW:CREDIT UNION
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/16/2003 | REVISION | 01/31/2003 | COMPLETED |
03/10/2003 | REVISION | 03/18/2003 | COMPLETED |
04/01/2003 | REVISION | 04/16/2003 | COMPLETED |
05/09/2003 | SITE | 06/09/2003 | COMPLETED |
09/16/2002 | 3RD PARTY REVIEW-COMMERCIAL | 10/30/2002 | COMPLETED |
09/16/2002 | SITE | 11/18/2002 | COMPLETED |
10/31/2002 | RESUBMITTAL | 11/18/2002 | COMPLETED |
12/06/2002 | REVISION | 12/24/2002 | COMPLETED |
Completed Inspections
Permit Status: C of o
Permit Number: T02CM04358
Permit Description: NEW:CREDIT UNION
Total Completed Inspections - 44
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/04/2002 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection 0000* |
12/04/2002 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection 0000* |
12/05/2002 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000*THIS INSPECTION APPROVED ON 12/4/02 BY RMYERS. |
12/09/2002 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | PLAN SUBMITTAL AND PERMIT REQUIRED FOR UNDERGROUND FIRE SPRINKLER PIPING. |
12/09/2002 | ELECTRIC - UFER | MCAPISTR | Approved | IVRS - Inspection 0000* |
12/17/2002 | ELECTRIC - UNDERGROUND | MCAPISTR | Approved | IVRS - Inspection 0000*FLOOR BOXES IN LOBBY. |
12/17/2002 | BUILDING PRE-SLAB | HLEYVA | Approved | IVRS - Inspection 0000*OK PRE SLAB @ MAIN BLDG. |
12/20/2002 | EXCAVATION/LAYOUT REBAR & ZON | RSUBA | Approved | IVRS - Inspection 0000*4 COL'S. |
01/13/2003 | FIRE SPKLR - UG PIPING FLUSH | JEGAN | Approved | IVRS - Inspection 0000* |
02/04/2003 | ROOF NAILING | LHANLY | Approved | IVRS - Inspection 0000* |
02/05/2003 | EXT METAL CLIPS/EXT SHEATHING | LHANLY | Approved | IVRS - Inspection 0000* |
02/13/2003 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | IVRS - Inspection 0000* |
02/14/2003 | FRAMING | LHANLY | Approved | IVRS - Inspection 0000* |
02/18/2003 | PLUMBING - GAS PRESSURE TEST | TRINIVJR | Approved | IVRS - Inspection 0000* |
02/20/2003 | ELECTRIC - INTERMEDIATE | JORTA | Approved | TELE, COUMM AND POWER FLOOR BOXES. |
02/24/2003 | SHEET ROCK NAILING | LHANLY | Approved | IVRS - Inspection 0000* |
03/20/2003 | PLUMBING - YARD WTR LINE/TEST | TRINIVJR | Approved | IVRS - Inspection 0000* 1.) 2" YARD WATER SERVICE FROM METER TO BLDG. SERVICE IS OK 2.) OK TO BACKFILL TRENCH. |
03/31/2003 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection 0000*OK FOR CEILING TILES. |
03/31/2003 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection 0000* |
03/31/2003 | FIRE SPKLR - OH PIPING & HYDRO | JEGAN | Approved | IVRS - Inspection 0000* |
03/31/2003 | BUILDING - TEMP POWER FOR TEST | LHANLY | Approved | IVRS - Inspection 0000* |
03/31/2003 | U VALUE FOR WINDOW | LHANLY | Approved | IVRS - Inspection 0000* |
03/31/2003 | BUILDING ABOVE CEILING | LHANLY | Approved | IVRS - Inspection 0000* |
04/01/2003 | MECHANICAL - TEMP PWR FOR TEST | JMILITEL | Approved | IVRS - Inspection 0000* |
04/01/2003 | PLUMBING - TEMP POWER FOR TEST | JSTANLEY | Approved | IVRS - Inspection 0000* |
04/02/2003 | ELECTRIC - TEMP POWER FOR TEST | JORTA | Approved | |
04/02/2003 | ELECTRIC - ABOVE CEILING | JORTA | Approved | IVRS - Inspection 0000* |
04/03/2003 | ELECTRIC - CABLE DROP | JORTA | Approved | IVRS - Inspection 0000* |
04/07/2003 | PLUMBING - GAS PRESS TEST FNL | TRINIVJR | Approved | IVRS - Inspection 0000*GAS VALVES FOR AC UNITS ON ROOF IS OK. |
04/24/2003 | RIGHT OF WAY - FINAL | DLEE | Approved | |
04/24/2003 | PLUMBING - FINAL | TRINIVJR | Approved | 1.) PLBG. FINAL IS OK 2.) OK FOR C OF O. |
04/24/2003 | OUTDOOR LIGHTING FINAL | JORTA | Approved | IVRS - Inspection 0000* |
04/25/2003 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000*OK FOR C OF O. 1.) PERMANENTLY LABEL EQUIPEMENT ON ROOF. 2.) PROVIDE PROPER FUSING IN ELEC. DISCONNECT. RECALL FOR INSPECTION. |
04/25/2003 | NPPO - FINAL | PGILBERT | Approved | |
04/25/2003 | LANDSCAPE - FINAL | PGILBERT | Approved | |
04/25/2003 | FIRE - FINAL | JEGAN | Approved | IVRS - Inspection 0000* |
04/25/2003 | FIRE SPKLR - FINAL | JEGAN | Approved | IVRS - Inspection 0000* |
04/30/2003 | STEM WALL/RETAINING WALL | LHANLY | Approved | IVRS - Inspection 0000* |
05/01/2003 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection 0000* |
05/01/2003 | ELECTRIC - FINAL | JORTA | Approved | IVRS - Inspection 0000* |
05/01/2003 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection 0000*1.) AD JUST DOORS TO RESTROOMS FOR MAX 5# PULL 2.) PROVIDE ELECTRIC FINAL. |
05/02/2003 | STUCCO MESH | LHANLY | Approved | |
06/10/2003 | PERMIT FINALED | LHANLY | Approved | |
06/10/2003 | ENGINEERING - FINAL | DROBERTS | Approved |