Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM04358
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/14/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
02/04/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000* | |
01/28/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*1.) SHELL 2.) ADD WASHER ON SIMPSON TIE DOWN @ EAST END. |
|
01/23/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000* 1.) STEEL BLOCKING @ ROOF LEDGER DELETED PER ADDENDUM 1. SHEAR PANELS SCREWED TO FLAT STRAPPING. 2.) TOP FLANGE HANGERS @ END OF LEDGER OK PER ENGINEER @ KC PRODUCTS. NO MINIMUM DISTANCE FROM CUT END OF LEDGER REG IF NAILS DON'T SPLIT WOOD. |
|
01/22/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*1.) 1/54.1 CALLS FOR STEEL BLOCKING @ JOIST (LEDGER) LEVEL. 2.) EXTERIOR SHEATHING IS OSB PER ADDENDUM 1-3A. 3.) I WILL CHECK ON TF HANGER NAILING REGS. |