Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY ALTERATION
Apply Date:
09/11/2002
Applicant:
BUILDWELL CONSTRUCTION CO L L C
Description:
REMODEL:SFR
Contractors:
  • BUILDWELL CONSTRUCTION CO L L C

Permit Reviews

Permit Number - T02CM04286
Permit Status: Expired
Permit Description: REMODEL:SFR
Start Date Submittal Complete Date Status  
09/11/2002 RESIDENTIAL BLDG/ZONING 10/09/2002 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T02CM04286
Permit Status: Expired
Permit Description: REMODEL:SFR
Total Outstanding Activity Conditions - 1
Date Name
09/11/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T02CM04286
Permite Description: REMODEL:SFR
Total Outstanding Inspections - 6
Last Inspection Date Description Inspector Results Comments
PLUMBING - GAS PRESS TEST FNL N/A Not Inspected
01/31/2003 SHEET ROCK NAILING N/A Partial Approval IVRS - Inspection 0000*/ 1) NEED DWV WATER TEST PER UPC 712.2 2) INSTALL 2 EACH 8' GROUND RODS AT LEAST 6' APART AND CONNECTED TO PANEL WITH MINIMUM #4 SOLID COPPER CONDUCTOR 3) BOND GAS LINE WITH #4 BOND 4) LABEL SERVICE PANEL 5) INSTALL MAINTENCE GFCI 20 AMP OUTLET 6) LAUNDRY BOX MUST BE 36" ABOVE FLOOR
08/20/2004 BUILDING - FINAL N/A Not ready for Inspection IVRS - Inspection :*/ 1) NOT READY PER OWNER
08/20/2004 ELECTRIC - FINAL N/A Not ready for Inspection IVRS - Inspection :*
08/20/2004 PLUMBING - FINAL N/A Not ready for Inspection IVRS - Inspection :*
08/20/2004 MECHANICAL - FINAL N/A Not ready for Inspection IVRS - Inspection :*

Completed Inspections

Permit Status: Expired
Permit Number: T02CM04286
Permit Description: REMODEL:SFR
Total Completed Inspections - 8
Date Description Inspector Results Comments
10/23/2002 MECHANICAL - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
10/23/2002 PLUMBING - GAS PRESSURE TEST RFREIDIN Approved IVRS - Inspection 0000*
10/23/2002 PLUMBING - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*/ 1) FINISH WATER LINES, PUT PRESSURE TEST ON OR OPERATING PRESSURE . LEAVE OPEN
10/23/2002 PLUMBING - ROUGH, SOIL RFREIDIN Approved IVRS - Inspection 0000*
10/23/2002 ELECTRIC - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
10/23/2002 FRAMING RFREIDIN Approved IVRS - Inspection 0000*
10/31/2002 ELECTRIC - TEMPORARY SERVICE EDURAZO Approved IVRS - Inspection 0999*/ 1) NO ACCESS-8:30 AM
03/13/2003 ELECTRIC - CABLE DROP ROHAVER Approved IVRS - Inspection 0000*

Documents

File Name Document Type  
None DOCUMENTS VIEW