Inspection History Details
Inspection Status: Partial Approval
Inspection History: SHEET ROCK NAILING
Permit Number - T02CM04286
Inspection Description - SHEET ROCK NAILING
Inspection Status - Partial Approval
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/31/2003 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection 0000*/ 1) NEED DWV WATER TEST PER UPC 712.2 2) INSTALL 2 EACH 8' GROUND RODS AT LEAST 6' APART AND CONNECTED TO PANEL WITH MINIMUM #4 SOLID COPPER CONDUCTOR 3) BOND GAS LINE WITH #4 BOND 4) LABEL SERVICE PANEL 5) INSTALL MAINTENCE GFCI 20 AMP OUTLET 6) LAUNDRY BOX MUST BE 36" ABOVE FLOOR |