Permit: T02CM04286

Parcel: 117062310


Addresses:

244 S RAILROAD AV


Inspection Status: Partial Approval

Inspection History: SHEET ROCK NAILING

Permit Number - T02CM04286

Inspection Description - SHEET ROCK NAILING

Inspection Status - Partial Approval

Date Description Inspector Results Comments
01/31/2003 SHEET ROCK NAILING Partial Approval IVRS - Inspection 0000*/ 1) NEED DWV WATER TEST PER UPC 712.2 2) INSTALL 2 EACH 8' GROUND RODS AT LEAST 6' APART AND CONNECTED TO PANEL WITH MINIMUM #4 SOLID COPPER CONDUCTOR 3) BOND GAS LINE WITH #4 BOND 4) LABEL SERVICE PANEL 5) INSTALL MAINTENCE GFCI 20 AMP OUTLET 6) LAUNDRY BOX MUST BE 36" ABOVE FLOOR